ADS126xEVM Software
3.4.5
Tab 5: GPIO
Tab 5, shown in
Figure
The GPIO Functions controls select the GPIO direction and logic value. Note that the GPIO logic levels
are referenced to the analog supply voltage (5V-logic). The Value radio buttons serve dual purposes as
both controls and indicators. Value indicates the logic value when configured as an input, and controls the
logic value when configured as an output. The Value buttons are grayed out until the GPIO function is
enabled on the respective channel. Controlling the GPIO value does nothing when configured as an input.
Clicking Read GPIO or modifying any of controls on this tab reads the GPIODAT register and updates all
value indicators.
NOTE: The GPIODAT register bits corresponding to GPIO inputs are read-only, and the GPIODAT
register bits corresponding to GPIO outputs are write-only. Therefore, you cannot read back
any GPIO output values from the GPIODAT register.
Store a copy of the GPIODAT register settings in memory (as this software does) in order to
recall the GPIO output configuration from memory.
NOTE: The software does not allow for simultaneous GPIO, Test DAC, IDAC, or VBIAS functions to
be enabled on the same pin.
24
ADS126xEVM-PDK
21, controls the GPIO functions available on the AIN3-AIN9 and AINCOM pins.
5 GPIO
Figure 21. Tab 5 Settings