Menù 12 - Mitsubishi Electric i-BX-N Technical Manual

Table of Contents

Advertisement

TM_i-BX(-N)_NC05_00_06_20_EN
2.4.12
MENÙ 12
Num Par
Description
P1200
Protocol BMS setting (1=CAREL RS485; 2=ModBus RS485; 3=pCOload local)
P1201
Setting BMS speed (0: 1200; 1: 2400; 2: 4800; 3: 9600; 4: 19200)
P1202
Address of the controller in a supervisory system network n.1
P1214
Disable the automatic management of alarm buzzer (0: Device is controlled by system variable
BUZZER; 1: Device is controlled by global variables)
P1215
Backlight always on setting
2.4.13
MENÙ 13
Num Par
Description
P1300
Enable Analogic input B1 (0:NO; 1:YES)
P1301
Type of NTC of B1 (0: NTC; 1: NTC-HT)
P1302
Enable Analogic input B2 (0:NO; 1:YES)
P1303
Type of NTC of B2 (0: NTC; 1: NTC-HT)
P1305
Type of NTC of B3 (0: NTC; 1: NTC-HT)
P1306
Enable Analogic input B4 (0:NO; 1:YES)
P1307
Type of NTC of B4 (0: NTC; 1: NTC-HT)
P1309
Type of NTC of B5 (0: NTC; 1: NTC-HT)
P130I
Unit model 0: AWR MTD; 1: WWR MTD; 2: BWR MTD; 3: i-KIR; 4: AW HT; 5: WWR HT; 6: BWR
HT; 7: WW HT; 8: BW HT; 9: WWR DHW; 10: BWR DHW; 11: AWR DHW; 12: i-NRG; 13: i-KIR
CV; 14: i-BX(N)
P130K
Enable EVD driver (0:NO; 1:YES)
P130S
Gas type (1=R134a;2=R404A;3= R407C;4=R410A; 10=R744)
P130U
Set high pressure alarm by transducer
P130V
Total numbers of compressor
P130W
Unit Air Water (0: UNIT WATER/WATER; 1: UNIT AIR/WATER)
P130X
Unit Reversible (0: NO; 1: YES)
P130Y
DHW production method (0: Dedicated exchanger; 1: 3way valve)
P130Z
Unit Reversible (0: Only heat; 1: Heat+Cool)
P1310
Enable Analogic input B6 (0: NO; 1: YES)
P1311
Type of NTC of B6 (0: NTC; 1: NTC-HT)
P1312
Enable Analogic input B7 (0: NO; 1: YES)
P1313
Enable Analogic input B8 (0: NO; 1: YES)
P1314
Type of NTC of B8 (0: NTC; 1: NTC-HT)
P1315
Enable Analogic input B9 (0: NO; 1: YES)
P1316
Type of NTC of B9 (0: NTC; 1: NTC-HT)
P1317
Enable Analogic input B10 (0: NO; 1: YES)
P1318
Type of NTC of B10 (0: NTC; 1: NTC-HT)
P1319
Enable Analogic input B11 (0: NO; 1: YES)
P131A
Hysteresis high pressure compressor/s
P131B
Number of retry for high pressure alarm
P131C
Set low pressure alarm by transducer
P131D
Hysteresis low pressure compressor/s
P131E
Low pressure alarm delay time at start compressor/s
P131F
Low pressure alarm delay time in steady operating compressor/s
P131G
Number of retry for low pressure alarm
P131H
Delay time between On compressors from On plant pump
P131I
Custom discharge maximum pressure value
P131J
Delay time Off plant pump from Off compressors
P131K
Enable independent equalization (0: NO; 1: YES)
P131L
Delay time Off DHW from Off compressors
MEHITS S.p.A.
TECHNICAL MANUAL
Default
2
4
1
0
0
Default
1
0
1
0
0
1
0
0
14
1
4
39.5
1
1
0
1
1
0
0
0
0
1
0
1
1
0
1
3.0
3
2.1
0.7
240
5
3
30
37.0
60
1
60
22
Version NC05 - Translation of the Original Instructions
Unit
Min.
Max.
-
0
3
baud
0
4
-
1
207
-
0
1
-
0
1
Unit
Min.
Max.
-
0
1
-
0
1
-
0
1
-
0
1
-
0
1
-
0
1
-
0
1
-
0
1
-
0
14
-
0
1
-
1
15
Bar
0
50.0
-
1
1
-
0
1
-
0
1
-
0
1
-
0
1
-
0
1
-
0
1
-
0
1
-
0
1
-
0
1
-
0
1
-
0
1
-
0
1
-
0
1
-
0
1
Bar
0
9.9
-
1
5
Bar
0
50.0
Bar
0.5
9.9
s
0
999
s
0
999
min
1
5
s
0
9999
Bar
0
99.9
s
0
9999
-
0
1
s
0
9999