Menù 06; Menù 07; Menù 08 - Mitsubishi Electric i-BX-N Technical Manual

Table of Contents

Advertisement

TM_i-BX(-N)_NC05_00_06_20_EN
2.4.7
MENÙ 06
Num Par
Description
P0603
Maximum speed of plant pump for 1st curve
P0604
Maximum speed of plant pump for 2nd curve
P0605
Maximum speed of plant pump for 3rd curve
P0606
Maximum speed of plant pump for 4th curve
P0609
Minimum speed of DHW pump
P0610
Maximum speed of DHW pump
P0611
Set delta T for overboost function
P0612
Differential delta Overboost
P0613
Differential DHW to start the thermoregulation
P0614
Set prevention high temperature plant (Only heating mode)
P0615
Number of retry for high pressure prevention (Only heating mode)
P0616
Delay to ON for the heaters
P0617
Integral time for switch ON the heaters
P0618
Delay to ON for the boiler
P0619
Integral time for switch ON the boiler
P0620
Force heaters in manual mode (0: Auto; 1: Manual)
P0621
Plant antifreeze heaters setpoint
P0622
Plant antifreeze heaters differential
P0623
Reset antifreeze alarm plant size
P0634
Plant exchanger antifreeze alarm setpiont
P0635
Plant exchanger antifreeze alarm differential
P0636
Max temperature to stop the heat pump
P0637
Type regulation plant (0: Outlet; 1: Inlet)
P0638
Differential to stop oil recovery for low temperature
P0639
Out plant temperature threshold to stop oil recovery
2.4.8
MENÙ 07
Num Par
Description
P0708
Antifreeze alarm setpoint geotherm circuit
P0709
Geothermal antifreeze alarm differential
P0710
Geo antifreeze heaters setpoint
P0711
Geo antifreeze heaters differential
P0712
Enable the heaters for coil of geo (0:NO; 1:YES)
2.4.9
MENÙ 08
Num Par
Description
P0801
Set high press.end defrost
P0802
Enable external probe control for defrost (0:NO; 1:YES)
P0803
Dripping time
P0804
Defrost maximum time
P0805
Defrost interval time
P0806
Low pressure setpoint to force the defrost
P0807
Delay to force the defrost
P0808
Start condition for defrost
P0809
Defrost number
P0810
External setpoint for defrost control
P0811
Set temperature start defrost
P0812
Diff dewpoint start defrost
MEHITS S.p.A.
TECHNICAL MANUAL
Default
7
8
9
10
7.0
10.0
10.0
3.0
5.0
60.0
3
60
0
60
0
0
4.0
3.0
1
4.0
3.0
90.0
0
2.0
58.0
Default
4.0
3.0
4.0
4.0
0
Default
25.0
1
0
10
30
1.5
30
5.3
0
12.0
0.0
0.0
20
Version NC05 - Translation of the Original Instructions
Unit
Min.
Max.
V
0
10
V
0
10
V
0
10
V
0
10
V
0
99.9
V
0
100
°C
0
999.9
°C
0
99.9
°C
0
99.9
Bar
0
999.9
-
1
999
min
0
500
s
0
999
s
0
500
s
0
999
-
0
1
°C
-999.9
999.9
°C
0
99.9
-
0
1
°C
-99.9
99.9
°C
0
99.9
°C
0
999.9
-
0
1
°C
0
99.9
°C
-999.9
999.9
Unit
Min.
Max.
°C
-999.9
999.9
°C
0
999.9
°C
-999.9
999.9
°C
0
99.9
-
0
1
Unit
Min.
Max.
Bar
-1.0
99.9
-
0
1
s
0
999
min
1
999
min
0
999
Bar
-1.0
99.9
s
0
999
Bar
-3276.8
3276.7
-
0
32767
°C
0.0
99.9
°C
-99.9
99.9
°C
0
9.9