Gaggia GE compact Instruction Booklet page 31

Professional coffee machine
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 22
To programme the other units, press the specific pro-
gramming key of each unit and carry out the same
operations as undertaken on unit 1. In this case any
variations in the measures are activated only on the
unit on which one is actually working.
7.2
COFFEE DELIVERY
On pressing the corresponding key T1-T2-T3 or T4, the
corresponding delivery solenoid valves are activated
for the time necessary to obtain the required amount of
product as previously programmed (volumetric check).
The LED relative to the selected measure remains on for
the entire coffee delivery time.
The delivery in progress may be suspended before ac-
tually reaching the desired programmed product quantity
by pressing any of the measure keys present on the
keyboard of the unit used for product delivery.
It is also possible to obtain simultaneous coffee delivery
from all the machine units.
7.3
CONTINUOUS COFFEE
MEASURES
For continuous coffee measure delivery press key T5
from the keyboard corresponding to the unit on which
one wishes to operate.
The LED corresponding to key T5 will remain on for the
entire delivery operation.
IMPORTANT ! Avoid keeping it pressed for more than
5 seconds or it will enter the programming mode.
Coffee delivery will continue until measure stop by
pressing key T5, or on obtaining the maximum amount
of product which can be obtained through volumetric
control (6000 impulses) or by means of delivery Time-
out function.
IMPORTANT ! The start of the relative "continuous"
cycle occurs on the release (within 5 seconds) of key T5
and not on pressing of the same. While the STOP function
may be obtained by pressing it a second time.
T1
T1
31
ENGLISh
T5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gd compact

Table of Contents