7.1
COFFEE MEASURE
PROGRAMMING
The measured amounts of coffee may be modified
(by means of volumetric checking) and memorized as
follows:
- press key T5 (of keyboard relative to group 1) and
keep pressed for over 5 seconds and check that
all the keyboard leds come on. In which case, (by
operating on the keyboard relative to group 1) all
the units will be programmed, while by pressing key
T5 of another unit, only the programming of the unit
on which one is operating is possible.
IMPORTANT !! The settings made on unit 1 (operating
on the first keyboard) will be automatically copied on
to all the other units.
Press the key corresponding to the measure to be
programmed (key T1 for example) within 30 seconds
(programming time-out).
The led relative to T5 will remain on, on all keyboards
and the led relative to the measure being programmed
will also come on (on all the keyboards). During this state
and for the entire coffee measure programming time
duration, the solenoid valve and pump are activated.
Note: If none of the keys are pressed within 30 seconds,
it will automatically escape from programming mode.
On pressing key T1 coffee delivery begins, once the
required amount of coffee is obtained press key T1
again or any other of the keys of the unit keyboard in
order to suspend coffee delivery. The new impulse value
of the measure is thereby memorized on the EPROM.
Both the solenoid valve and the pump are de-activated
thereby suspending product delivery and all the key-
board leds go out.
To proceed with a new programming operation of other
coffee measures T2-T3-T4 (providing that the program-
ming time out time of 30 sec is not exceeded) simply
repeat the same operations with the same sequence as
undertaken for key T1.
Press key T5 to immediately escape from the program-
ming stage.
IMPORTANT: Should the "PRE-INFUSION" function
be active (see par. 7.5). Wait until the pre-infusion fun-
ction is complete before stopping delivery in progress.
NOTE: During the programming of a unit the function
of the other units is deactivated as well as tea dispen-
sing.