5 - INSTALLATION
A - MAINS SUPPLY
B - DISCHARGE DUCTS
C - PROTECTION SWITCH
D - PURIFIER
E - DRIP BOWL
F - POWER CABLE
Caution! The appliance is not suitable for installation in
areas where a water jet can be used.
Before proceeding with installation check that:
1 there are no bumps, signs of knocks or deformities.
2 there are no damp patches or marks which could lead one to assume
that the packaging has been exposed to the elements
3 there are no signs of tampering
Once one is satisfied that transportation has been correctly effected
proceed with installation.
Proceed with installation following the instructions according to the
sequence as described below.
N.B. The least height of the support's top must be 110cm. (The higher
surface of the appliance shall however be at least 1,5 m from the
ground level)
5.1
WATER CONNECTION
Important: The machine must be supplied with water of
over 8°F hardness.
The installation of a water softener is recommended for the machine
water supply.
Check that the water mains to which connection is to be made supplies
drinking water.
- Connect purifier (D) to the water mains (A).
NB: before connecting the purifier to the machine, wash out
thoroughly until the water becomes clear, then proceed to
connect the purifier to the machine.
- Connect the drain cup (E) to the drainage pipe (B)
- Should the mains pressure be higher than 0,5 MPa a pressure redu-
cer balanced for high pressure should be installed (device in which
any mains pressure increase does not effect the output pressure).
Should the machine be moved to a different place, the fitting unit must
be replaced with a new one.
C
D
A
B
Fig.5.01
5.2
ELECTRICAL CONNECTION
Important ! Before proceeding with electrical connection
it is necessary to check to ensure that the voltage rating
corresponds with that indicated on the CE plate and on the
connection plate on the power supply cable.
The appliance shall be placed so that the plug is easily accessible.
Check to ensure that the electrical supply line is able to support the
machine load (see chap. 4 – technical features table).
Connect to an earthing socket which complies with current legisla-
tion.
Check that the power supply cable is efficient and that it complies with
national and European safety standards.
The user must undertake to power the machine protecting the power line
using a suitable safety switch (cut-out) that complies with the legislation
in force in the actual country itself.
Connect the power cable (F) to the electric line using a plug, or in
the case of fixed installation, using a multi-polar switch (C) for mains
separation, with a contact distance of at least 3 mm.
For voltage change refer to the diagram shown on the general mains
switch box.
The yellow-green coloured cable MUST be connected to the room's
earthing system.