Sampling
5.
Use the cursor buttons and the [-] [+] buttons to make settings for sampling.
Parameter
REC LEVEL
AUTO START
Signal flow
Analog signal
Start sampling
6.
Press the [F1] (STBY) button.
The sampling standby screen will appear.
7.
Start sampling.
If you set AUTO START "OFF" in step 5
Sampling will begin when you press the [F2] (START) button. Produce sound on the device that's connected to the SPD-SX.
While sampling is taking place, the screen will indicate "NOW SAMPLING... "
If you set AUTO START to anything other than "OFF" in step 5
Produce sound on the device that's connected to the SPD-SX; sampling will begin when the input signal exceeds the level
specified by AUTO START.
While sampling is occurring, the screen will indicate "NOW SAMPLING... "
30
Value
Explanation
Adjusts the volume at which sampling will occur.
Produce sound on the device that's connected to the SPD-SX, and adjust the volume until it's
as high as you can get it without causing the level overload indication to appear.
0–100
Level meter
When you press the [F2] (START) button, sampling will begin the moment that the input
signal exceeds the level you specified here.
OFF, 1–15
If this is "OFF, " sampling will begin the moment you press the [F2] (START) button.
Specifies the kit and pad to which the sampled wave will be assigned.
KIT001–100, PAD1–9
* You can only select an empty pad, one which has no wave assigned to it.
AUDIO IN jacks
Adjust appropriately for
the connected device
Digital signal
[GAIN] knob
Level overload indication
REC LEVEL
Level meter
Adjust to avoid the level
overload indication
COMPUTER connector