Appendix 2 Load Cell Pin; Appendix 3 Modbus Data Address Table - Excell H3 Series User Manual

Weighing scale
Hide thumbs Also See for H3 Series:
Table of Contents

Advertisement

EXCELL PRECISION CO., LTD.

Appendix 2 Load Cell PIN

5-pin female
connector

Appendix 3 MODBUS Data Address Table

MODBUS Data Address Table I
Data Register
Function Code 03 (Read
Modbus
SCALE
40004 ~ 40005
As display value
Function Code 06 and 16 (Write)
41000 ~ 41001
Pre-tare value
41014 ~ 41015
LO limit value
41018 ~ 41019
HI limit value
0201813X
Load Cell
Weighing scale
(AW, HW, FD, RW, TW)
1
EXC+
2
EXC -
3
SIG+
4
SIG -
5
GND
)
Function Code 01 (Read)
Modbus
00000
00001
00002
00003
00059
00060
00061
shield
Load Cell cable
Bit I/O
SCALE Output
Modbus
Stable status
Zero status
Gross
Net
Hi
Ok
Lo
25
EXC+
SIG+
EXC-
SIG-
Bit I/O
Function Code 05 and 15 (Write)
SCALE Input
01000
Zero
01001
01002
Tare
01003
Clear tare
ZSME300000366

Hide quick links:

Advertisement

Table of Contents
loading