EXCELL PRECISION CO., LTD.
Stable Transmission Only Weight Value Is Transmitted (r n P 14)
No +/-. If display is 1.000kg , transmit
r n P 15  Enter Serial number, Reply Serial Number and Weight
Enter the serial number (up to 64 characters), if you enter the SN number: SN0001
it displays 1.000kg, etc. After stable, RS232 output format: SN0001,001.000kg
r n P 16  Continuous Output Contains High, Low, Ok Status
The continuous output format is similar to r n p 2, the first code of HEAD2 is gross/net weight,
and the second code output includes High(H), Low(L), Ok(O) states, if Low is set to 0.500kg and
High is set to 1.000kg, then 0.876 kg output is as follows.
S
T
,
G
O
HEAD1
,
HEAD2
F5
Function
r n p 0
RS232 command mode
r n p 1
Stable transmission
r n p 2
Continuous transmission.
Press
r n p 3
totalized simple format
Press
r n p 4
totalized complete format.
Stable transmission in totalizing
mode (After return to zero,
r n p 5
transmit next stable weight which
is > +10d)
Press
r n p 6
simple free format
Press
r n p 7
complete free format
While use Hold, press
r n p 8
to transmit same format as (r n P
1) and (r n P 2)
r n p 9
Continuous Transmission (Brazil)
or
r n p 10
Transmission (Brazil)
Print after removing goods (5%
r n p 11
mode)
0201813X
,
+
0
,
DATA
key to transmit
key to transmit
key to transmit
key to transmit
key
key
1
.
DATA
.
8
7
6
Press
key
Press
Once received read weight command, transmit weight in
same format as r n p 1.
After return to zero, transmit next stable weight.
RS232 transmit continuously. Keypad has no effect.
Transmit when
Transmit when
weight change
weight change
>±10d,
>±10d,
Transmit when
Transmit when
weight change
weight change
>±10d,
>±10d,
No transmission
No transmission
Transmit when
Transmit when
weight change
weight change
>±10d,
>±10d,
Transmit when
Transmit when
weight change
weight change
>±10d,
>±10d,
Transmit as
No transmission
stable weight
>±10d
Continuous
Continuous
transmission
transmission
RS232 transmit
RS232 transmit
After placing item and become stable, beep twice. RS232
transmit item weight after item is removed.
17
0
0
0
<CR><LF>
<CR><LF>
k
g
<CR> <LF>
UNIT
CR
LF
key
Press
twice after zeroing
Print TOTAL and
clears totalized
values
Print TOTAL and
clears totalized
values
Print TOTAL and
clears totalized
values
Print TOTAL and
clears totalized
values
Print TOTAL and
clears totalized
values
No transmission,
totalized values not
cleared
Continuous
transmission,
totalized values not
cleared
Print TOTAL and
clears totalized
values
ZSME300000366
<CR> <LF>
CR
LF
, if
key

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents