F11 Id Code Setting - Excell H3 Series User Manual

Weighing scale
Hide thumbs Also See for H3 Series:
Table of Contents

Advertisement

EXCELL PRECISION CO., LTD.
4. Repeat above Steps 2-3 to make 10 or more measurements, then compare deviations
among these 10 measurements.
How to exit hold mode:
Suppose Weight Hold Range is set as 1.000 kg, and the weight held after stable is 8.543 kg
(now the weight is held with buzzer already beeped, weight value will not change), when
weight change (increment or decrement) equals or exceeds Weight Hold Range (i.e. 8.543kg
+ 1.000kg or 8.543kg – 1.000kg), scale will automatically exit hold mode, then scale will
recalculate holding weight (i.e. changing weight is displayed in real time until weight becomes
stable, and scale enters hold mode). This whole hold mode entry and exit process will repeat
continuously.

3-6 F11 ID Code Setting

(must be used with r n P 1, r n P 2, r n P 8 of F5)
Press
Press
key
Press
key
RS232 DATA FORMAT
Stable transmission (
1. e.g. Machine ID code is 10.
The gross weight (+0.876 kg) shows as below, after stable: (no tare or pre-tare mode)
1
0
S
T
ID
HEAD1
2. e.g. Machine ID code is 00. (Not using Machine ID function.)
The net weight (-1.568 lb) shows as below without weight stability: (under tare or pre-tare mode)
U
S
,
N
HEAD1
,
HEAD2,
0201813X
key or
key to select F11
Machine ID code setting:
Use
(1) "00": RS-232 does not transmit Machine ID.
(2) "01~99": RS-232 transmits Machine ID.
r n P 1
), Continuous (
,
G
S
,
+
,
HEAD2
,
T
,
-
0
0
and
to set 01 ~ 99. Default setting: 00
r n P 2
), Press
0
0
0
.
8
DATA
1
.
5
6
8
DATA
20
key to transmit (
7
6
k
g
<CR> <LF>
UNIT
l
b
<CR> <LF>
UNIT
ZSME300000366
r n P 8
)