EXCELL PRECISION CO., LTD. Table of Contents PREPARING TO USE THE SCALE ....................2 PRECAUTIONS FOR USE ......................2 CHAPTER 1 INTRODUCTION ..................... 4 1-1 P ....................4 RODUCTION NTRODUCTION 1-2 D ......................4 ISPLAY ESCRIPTION 1-3 K ..................5...
EXCELL PRECISION CO., LTD. Thank for your purchasing of our EXCELL Weighing Scale. To guide you to use our product correctly, please read this User Manual carefully to extend the life of machine and to avoid error. Preparing to Use the Scale 1.
Page 4
EXCELL PRECISION CO., LTD. 9. Due to the storage battery adopt the advanced free-maintaining technique, customers need not to replenish electrolyte. The scale should be recharged every 3 months to prevent failure of the internal rechargeable battery. 1. The battery should be charged for 8~10 hours.
EXCELL PRECISION CO., LTD. Chapter 1 Introduction 1-1 Production Introduction 1. High performance A/D converter 0.3 uv/D high sensitivity zero point adjustable range -2mV~ +5mV Sampling speed 15 times/second use range -4mV ~ +30mV load cell stimulate power source 5V DC ±2% 100mA ...
EXCELL PRECISION CO., LTD. 1-4 Power Description Battery 6V 4Ah Rechargeable battery Power Plugged in 110V / 220V AC No backlight 26 mA Single display with Power consumption with 32 mA backlight 1X350Ω load cell Dual display with 40 mA...
EXCELL PRECISION CO., LTD. Chapter 2 General Operation Description 2-1 Backlight Function Press key to select the display backlight mode: bL. Auto “Auto Backlight” mode. When the weight is over 10d or any key is pressed, the display backlight will be switched on. When the weight returns to zero (the weight on platform is less than 10d), the display backlight will switch off after 10 seconds.
EXCELL PRECISION CO., LTD. off. Recall pretare value key the display shows pretare value Press then In Tare mode, the Preset tare function is disabled. The indicators with two weighing ranges can NOT pre-set the tare value larger than the first weighing range.
Page 10
EXCELL PRECISION CO., LTD. Preset Single point (preset low limit only): After “preset low limit” procedures is completed and the display shows . This means that the “preset then press key again, the display shows single point” procedure is completed.
EXCELL PRECISION CO., LTD. 3. Clearing Check-weighing Values (not available in 4/5/10 key models) key Recall “Low limit Press key then press key, and then press key again Clear “High limit value” and “Beeper value” value”. Then press key 6 times continuously ...
EXCELL PRECISION CO., LTD. Range 2 and Range 1 and the two symbol indications are off. 2-3-2 Check Weighing Refer to the operation of check weighing in weighing function. 2-3-3 Totalizing Refer to the operation of totalizing in weighing function.
EXCELL PRECISION CO., LTD. 3-1 F4 Check Weighing Configurations If hold mode ( ) is set, accessing to F4 is denied. Press key to select F4 Press Press key for 5 times to clear HI, OK, LO values Preset “LO value”...
EXCELL PRECISION CO., LTD. 3-2 F5 RS-232 Output Setting (Option) Make J1、J3 on RS232 short circuit, when connecting to computer. key to select F5. Press :use Transmission mode key to select r n P 0 ~ r n P 14 and press...
Page 15
EXCELL PRECISION CO., LTD. RS-232 Data Format Command mode (r n P 0) Command Function Return message definition T <CR> <LF> Clear tare N P <CR> <LF> already pre-tared C T <CR> <LF> successful T <CR> <LF> Tare N P <CR> <LF> already pre-tared M T <CR>...
Page 16
EXCELL PRECISION CO., LTD. 1. The gross weight (+0.876 kg) shows as below, after stable: (no tare or pre-tare mode) <CR> <LF> HEAD1 , HEAD2 DATA UNIT CR 2. The net weight (-1.568 lb) shows as below without weight stability: (under tare or pre-tare mode) <CR>...
Page 17
EXCELL PRECISION CO., LTD. Stable Transmission in totalizing mode (r n P 5) WT/UNIT ( kg / lb ) - - - - - - - - - - - - - - The scale is stable 0001 1.0000 ...
Page 18
EXCELL PRECISION CO., LTD. Stable Transmission Only Weight Value Is Transmitted (r n P 14) No +/-. If display is 1.000kg , transmit <CR> <LF> DATA r n P 15 Enter Serial number, Reply Serial Number and Weight Enter the serial number (up to 64 characters), if you enter the SN number: SN0001 , if <CR><LF>...
EXCELL PRECISION CO., LTD. Press Press Press Function twice after zeroing RS232 transmit only “OK” item weight after item is removed. Print after removing goods (OK r n p 12 No transmission while in “HI” or “LO”. mode) Use MODBUS to transmit weight, and need to use with F11...
Page 20
EXCELL PRECISION CO., LTD. hold 0 = No hold function hold 1 = For varying weighing value, the scale will automatically hold the maximum weighing value to display. To exit hold mode, press any key (except the key). hold 2 = After the scale is stabilized, the scale will automatically hold the display value( not changeable due to external variables)To exit hold mode, press any key.( except the...
EXCELL PRECISION CO., LTD. 4. Repeat above Steps 2-3 to make 10 or more measurements, then compare deviations among these 10 measurements. How to exit hold mode: Suppose Weight Hold Range is set as 1.000 kg, and the weight held after stable is 8.543 kg (now the weight is held with buzzer already beeped, weight value will not change), when weight change (increment or decrement) equals or exceeds Weight Hold Range (i.e.
EXCELL PRECISION CO., LTD. 3-7 F12 Print Key ( ) Function Setting Press key or key to select F12 Print key setting: to set 0~2. Default setting: 0 Press P r F 0 If weight variation is beyond ±1d ~ ±10d, key print totalized weight.
EXCELL PRECISION CO., LTD. 3-8 F14 Customized Header Setting (r n P 6, r n P 7) CODE Description CODE Description No print. TICKET NO. DATE (Note: need FB530’s MINI_PRINTER to print) TIME (Note: need FB530’s MINI_PRINTER to print) F14 contains a 9-digit code. For example: 6 1 2 3 4 5 0 0 0 ○...
EXCELL PRECISION CO., LTD. Appendix 1 Option Card Description RS232 Output 1. Weighing scale (AW, HW, FD, RW, TW) RS232 card’s 6PIN cable connect to CN3 of mainboard SCALE RS232 SCALE PRINTER DB 9 (female) DB 9 (female) DB 9 (female) DB 9 (male) ...
Page 25
EXCELL PRECISION CO., LTD. Internally power supply from the system itself Do not connect any power supply to PIN4, PIN5 J1, J2 SHORT 4. Configuration OK, High, and Low can be set to NO (normally open, Type A) or NC (normally closed, Type B).
EXCELL PRECISION CO., LTD. MODBUS Data Address Table II (For Hitech and Pro-face Human Machine Interface) Bit I/O Data Register Bit I/O Function Code 01 (Read) Function Code 05 and 15 (Write) Function Code 03 (Read Modbus SCALE Modbus SCALE Output...