EXCELL PRECISION CO., LTD. TABLE OF CONTENTS Instruction For Use........................3 Preparations Before Using ......................3 Chapter 1 Display and Keypad Descriptions ................4 1-1 D ......................4 ISPLAY ESCRIPTIONS 1-2 S “3” ......................4 YMBOL CONS 1-3 K ......................5...
Page 4
EXCELL PRECISION CO., LTD. 2-10 W ....................... 29 EIGHT RESET 2-10-1 Upper Limit of Preset Weight................... 29 2-10-2 Clear Upper Limit of Preset Weight ................. 29 2-11 ID I ........................... 30 NPUT 2-12 ITEM I ........................30 NPUT 2-13 U .......................
EXCELL PRECISION CO., LTD. Thank you for purchasing EXCELL counting scale. In order to operate smoothly, to last the durability and to reduce chance of breakdown for this product, please read this manual carefully. Instruction For Use The scale should not be drenched by rain or water. (If it gets wet carelessly, please wipe it dry with a cloth.
EXCELL PRECISION CO., LTD. 1-3 Keypad Descriptions Double weighing units keypad _ double units conversion Q’TY SAMPL UNIT kg/lb PQRS WXYZ ‧ ‧ ‧ ‧ 10 sets of preset unit weight keypad _ preset unit weight function Q’TY SAMPL UNIT U.W.
Page 8
EXCELL PRECISION CO., LTD. Number key for setting the unit weight, quantity and etc. Clear key to clear the digits on the display. Sampling key to set the sample count. Unit weight key for setting the unit weight of sample.
EXCELL PRECISION CO., LTD. 1-4 Error Messages ⇒ Zero value is too high (OIML or NTEP > 10% full scale) ⇒ Zero value is low (OIML or NTEP < -10% full scale) ⇒ Internal value is more than 700000(use in factory calibration) ⇒...
EXCELL PRECISION CO., LTD. 1-5 Self-Test Mode Hold 0Z key to open the scale until the display show . Wait till display shows to enter “Self-Test Mode”. Press ⇒ check Software version number ⇒ check key and LCD、BL test Press ⇒...
EXCELL PRECISION CO., LTD. 1-5-1 Check Software Version Number Press MC Press MC 03004010 is software version number Show the maintenance number 034 for 1 second then return to 010 Press MC key ⇒ ESC CE key ⇒ Move cursor leftward T key ⇒...
EXCELL PRECISION CO., LTD. 1-5-2 Check key and LCD、 、 、 、 BL test press The number of LCD is count backward as 9~0 pattern The symbol and press backlight of LCD is on when it is odd number,conversly it is off.
EXCELL PRECISION CO., LTD. 1-5-3 Read AD Value press X X X X X X press Show the internal value key ⇒ ESC CE key ⇒ Move cursor leftward T key ⇒ Move cursor rightward MC key ⇒ ENTER check whether the internal value is within its normal range (range of carrying idler :100,000 ~ 700,000 ) ⇒...
EXCELL PRECISION CO., LTD. 1-5-6 Real Time Clock(RTC) read press press 08:38:50 2005/08/18 key ⇒ ESC CE key ⇒ Move cursor leftward T key ⇒ Move cursor rightward MC key ⇒ ENTER 12 code numbers standard for: year, month, day, hour, minute, second If the display shows 12 zeros and not flicker, it shows that free format PCB is not been connected to the main board or free format PCB RTC has not been installed.
EXCELL PRECISION CO., LTD. 1-5-7 RS232 (TXD and RXD short circuit test) Press PASS RS232 the operation of internal board is correct Press FAIL RS232 the operation of internal board fail or is not circuit key ⇒ ESC CE key ⇒ Move cursor leftward T key ⇒...
EXCELL PRECISION CO., LTD. 1-5-8 Read the Software Number of Free Format PCB press X X X X X X X X press software number of free format PCB key ⇒ ESC CE key ⇒ Move cursor leftward T key ⇒ Move cursor rightward MC key ⇒...
EXCELL PRECISION CO., LTD. 1-5-9 Read IC AD Value of Temperature press press Show IC AD value of temprature If shows “NOTMP” ⇒ no tempreture IC key ⇒ ESC CE key ⇒ Move cursor leftward T key ⇒ Move cursor rightward MC key ⇒...
EXCELL PRECISION CO., LTD. 1-5-10 Read AD Value of Battery Cell Volt press press AD value of volt key ⇒ ESC CE key ⇒ Move cursor leftward T key ⇒ Move cursor rightward MC key ⇒ ENTER If AD value of volt is less than 398, it will show (about 5.8V)
EXCELL PRECISION CO., LTD. Chapter 2 Operation 2-1 Power On SW Switch On (Press SW to location “ ”) Weight Unit Weight Quantity After stable, the scale will count back to zero. Weight Unit Weight Quantity Sampling Speed 600 ⇒...
EXCELL PRECISION CO., LTD. 2-4 Sampling Function 2-4-1 Unknown Unit Weight of a Weighed Object 1. Place the sampling object on platter: Weight on platter 2. Enter the quantity of the sample on platter: Weight on platter Enter the sampling quantity NOTE: The number of quantity column will flash 6 seconds.
EXCELL PRECISION CO., LTD. 2-4-3 Under Tare Status 1. Take the sample off the platter. The weight of the object on the platter 2. Input the quantity of the sample on the platter. The weight of the object on the platter...
EXCELL PRECISION CO., LTD. 2-5 Tare Function Operation 1. Place the packaging container on platter: Weight of packaging container 2. Press TARE 3. The scale will enter into counting mode after stable: → → → → 0← ← ← ←...
EXCELL PRECISION CO., LTD. 2-6 Pre-Tare Function Operation (Pre-Tare setting) is set up as . (no weight on platter) 1. No object on platter → → → → 0← ← ← ← Stable 2. Press TARE → → → → 0← ← ← ←...
EXCELL PRECISION CO., LTD. 2-7 Clear Off Pre-Tare Value After removing the object together with packaging container, weight column will display the negative weight value of the packaging container. Press key once again to cancel TARE the Pre-Tare value and return to zero. Then the tare and Pre-Tare symbol “3” will disappear.
EXCELL PRECISION CO., LTD. 2-8 Accumulation The accumulation counts are up to 99 counts, but the total quantity column is at most 6 digits. You can not do positive accumulation and negative accumulation at the same time. 2-8-1 Quantity Accumulation 1.
EXCELL PRECISION CO., LTD. 2-8-2 Weight Accumulation 1. Place an object on platter when unit weight display is 0: Stable Wight of the object on platter 2. Press key: 3. After scale is stable: Stable Accumulated total weight Accumulated total counts 4.
EXCELL PRECISION CO., LTD. 2-9 Quantity Preset It’s available to pre-set the upper limit of quantity under counting mode. If the counts are over the limit, the beeper makes warning sounds, and the weight column displays flashing 2-9-1 Upper Limit of Preset Quantity 1.
EXCELL PRECISION CO., LTD. 2-10 Weight Preset It’s available to pre-set the upper limit of weight. If the weights are over the limit, the beeper makes warning sounds, and the weight column displays flashing 2-10-1 Upper Limit of Preset Weight 1.
EXCELL PRECISION CO., LTD. 2-11 ID Input Press ZERO key, and the screen displays “ - - - - - - ”. Press 0 key before it disappears. ID could be set up to 12 digits. They can be numbers ( 0 ~ 9 ), English letters Input ID with number keys.
EXCELL PRECISION CO., LTD. 2-13 Unit Weight Preset The preset data could be save in up to 10 addresses Each address contains unit weight, pre-tare, ID and ITEM. 2-13-1 Pre-set Unit Weight Saving Operation (read-in) Use number key to input the unit weight. (The value is 0 or blank if not being set.)
EXCELL PRECISION CO., LTD. Chapter 3 External Calibration Setting Mode After starting machine, and the scale returns to zero, press key and the screen will ZERO display “ - - - - - - ”. Then, press key to enter external calibration function setting mode.
EXCELL PRECISION CO., LTD. 3-1-3 Stable Range Setting for Quantity Sampling Press Enter parameter 00 ~ 15 Previous setting according to demand Press key to save the setting data ⇒ ⇒ ⇒ ⇒ Exit ⇒ ⇒ ⇒ ⇒ Move the cursor leftward TARE ⇒...
EXCELL PRECISION CO., LTD. 3-1-4 Automatic Average Unit Weight Setting Press Enter parameter 00, 01 Previous setting according to demand press to save setting data ⇒ ⇒ ⇒ ⇒ Exit ⇒ ⇒ ⇒ ⇒ Move the cursor leftward TARE ⇒ ⇒ ⇒ ⇒ Move the cursor rightward ⇒...
EXCELL PRECISION CO., LTD. 3-1-6 Zero Display Range Setting Press Enter parameter 00 ~ 03 Previous setting according to demand Press to save the setting data ⇒ ⇒ ⇒ ⇒ Exit ⇒ ⇒ ⇒ ⇒ Move the cursor leftward TARE ⇒...
EXCELL PRECISION CO., LTD. 3-1-7 Zero Tracking Range Setting Press Enter parameter 00 ~ 03 Previous setting according to demand Press key to save setting data ⇒ ⇒ ⇒ ⇒ Exit ⇒ ⇒ ⇒ ⇒ Move the cursor leftward TARE ⇒...
EXCELL PRECISION CO., LTD. 3-1-13 Combination Key Setting Combination key represents kg/lb U.W.PST key; this key contains two functions: Unit switching 10 sets for unit weight preset Press Enter parameter 00, 01 Previous setting according to demand Press key to save the setting data ⇒...
EXCELL PRECISION CO., LTD. 3-2-1 External Weight Calibration Zero value can be calibrated separately from the weight calibration value. X X X If there is no temperature IC, the unit weight column will Press display X X X X X X X X X...
EXCELL PRECISION CO., LTD. 3-2-2 Gravity Adjustment It’s capable for users to reset and modify gravity for 9 times. If it’s the 10 revised gravity calibration, it needs to enter into to redo the “gravity calibration in operation location,” and the calibration time will be re-set to “1”.
Page 52
EXCELL PRECISION CO., LTD. Press to display historical revised data Display the current revised times, and the revised gravity in operation location. Press . to quit and back to previous level Press Press TARE Press MC key to enter into revising mode Display previous revised times and revised gravity in operation place.
EXCELL PRECISION CO., LTD. 3-3-3 Output Data Format Setting Enter parameter 00 ~ 07 Previous setting according to demand Press key to save setting data ⇒ ⇒ ⇒ ⇒ Exit ⇒ ⇒ ⇒ ⇒ Move the cursor leftward TARE ⇒ ⇒ ⇒ ⇒ Move the cursor rightward ⇒...
Page 57
EXCELL PRECISION CO., LTD. Example: Illustration for fixed format is described as below: Fixed format 2 Fixed format 1 “Press M+ key to transmit” “Press M+ key to transmit” xxxxxxx xxxxx ITEM: xxxxxxx xxxxx 2.480 2.480 2.000 2.000 0.080 0.080 0.400...
Page 58
EXCELL PRECISION CO., LTD. Fixed format 3 “Press MC key to transmit” (to print out total accumulation data, and clear data in memory) = = = = = = = = = = = 1500 ⇒ ⇒ ⇒ ⇒ Number of Counts ⇒...
Page 59
EXCELL PRECISION CO., LTD. 3-3-4 Output Counts Setting Per second in Continuous Transmission Press Enter parameter 00 ~ 04 Previous setting according to demand Press key to save setting data. ⇒ ⇒ ⇒ ⇒ Exit ⇒ ⇒ ⇒ ⇒ Move the cursor leftward TARE ⇒...
EXCELL PRECISION CO., LTD. 3-3-5 Operation Mode Setting Press Enter parameter 00 ~ 04 Previous setting according to demand Press key to save the setting data ⇒ ⇒ ⇒ ⇒ Exit ⇒ ⇒ ⇒ ⇒ Move the cursor leftward TARE ⇒...
Page 61
EXCELL PRECISION CO., LTD. Zebra printer output format 1. Press M+ key to transmit the data. “ “ <LF> ? <LF> G <LF> T <LF> PT PT PT PT PT <LF> N <LF> UW UW UW UW UW <LF> PCS PCS PCS PCS PCS PCS <LF>...
Page 62
EXCELL PRECISION CO., LTD. 2. Press MC key to transmit the data. “ “ <LF> <LF> TN <LF> TW <LF> TA <LF> <LF> <LF> TN: Total number TW: Total weights TA: Total quantities tn: Total number tw: Total weights ta: Total quantities NOTE: Fill in zero “0”...
EXCELL PRECISION CO., LTD. 3-3-7 Zero Reset Condition for Automatic Transmission Setting Press Enter parameter 00 ~ 99 Previous setting according to demand Press key to save the setting data ⇒ ⇒ ⇒ ⇒ Exit ⇒ ⇒ ⇒ ⇒ Move the cursor leftward TARE ⇒...
EXCELL PRECISION CO., LTD. Appendix 1 RS-232 Full Duplex Format Table 1. Command Format Illustration Command Format A Host Command Slave Command Return to zero Clear off pre-tare value Tare Clear off tare value Current net weight accumulation & count...
Page 67
EXCELL PRECISION CO., LTD. Table 2. Output Format Illustration General Format Gross , G S 4 5 6 b o z weight Net weight S T + 1 2 5 6 T Tare + 0 1 2 3 4 5 6 SP SP k g...