EXCELL PRECISION CO., LTD.
Preset Single point (preset low limit only):
After "preset low limit" procedures is completed and the display shows
then press
single point" procedure is completed.
NOTE
_
A
Setting for the status that LCD is on and the beeper beep:
0 = when stable, the beeper beeps and LCD is on.
1 = when stable, the beeper beeps; whether stable or not, LCD is on.
2 = whether stable or not, the beeper beeps and LCD is on.
3 = open warning device: when the weight is higher than HI value and the weight is
stable, LCD is on and Relay Card open.
B
Setting for the beep status:
0 = No beep
1 = OK (when the weight is over Low Limit & under or equal to High Limit.), the beeper
beeps.
2 = When the weight is under or equal to Low Limit & over High Limit, the beeper beeps.
Under Status in Preset Low Limit (preset single point only)
The BEEP, LCD mode should be fixed as follows:
Warning device setting
Set HI value and value of the beep, LCD mode should be fixed as follows:
When the weight equals to HI value, Relay Card open and the weight is accumulated. Press CE
key to dismiss the warning sound and the range of accumulated weight is [000.000]~[999999].
Clear warning accumulation
Press
key first and then press
Accumulated data is cleared automatically under following conditions
a. when shift among weight mode, counting mode and warning accumulation mode.
b. when shift the units
c. turn off the scale
Set relay low output: L1 => low output; L0=> no low output
LCD indication:
◆ To exit preset mode, please press
2. Recall Check-weighing Values
Press
Then press
Then press
Then press
0201813X
key again, the display shows
x
x
_
_
A
B
When over "Low Limit", the beeper beeps and
Whether stable or not, the beeper beeps and LCD indication is on
(not available in 4/5 key models)
A
(not available in 4/5 key models)
10d Low Limit
(not available in 4/5/10 key models)
key then press
key again
key again
key again
.
key to clear all accumulated data.
High Limit
key.
key Recall "Low limit value"
Recall "High limit value"
Recall "Beeper value"
Back to the beginning
9
. This means that the "preset
is off
ZSME300000366
.
,