Counting scale
Table of Contents

Advertisement

Quick Links

H4 Series and X Series
Counting Scale
User Manual
© EXCELL PRECISION CO., LTD. 2021. All rights reserved worldwide.
The information contained herein is the property of EXCELL PRECISION CO., LTD. and is
supplied without liability for errors or omissions. No part may be reproduced or used except as
authorized by contract or other written permission. The copyright and the foregoing restriction
on reproduction and use extend to all media in which the information may be embodied.

Advertisement

Table of Contents
loading

Summary of Contents for Excell H4 Series

  • Page 1 © EXCELL PRECISION CO., LTD. 2021. All rights reserved worldwide. The information contained herein is the property of EXCELL PRECISION CO., LTD. and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorized by contract or other written permission.
  • Page 3: Table Of Contents

    EXCELL PRECISION CO., LTD. Table of Contents PRECAUTIONS FOR USE ......................3 PREPARATIONS BEFORE USING ..................... 3 CHAPTER 1 DISPLAY AND KEYPAD DESCRIPTIONS ............. 5 1-1 D ......................5 ISPLAY ESCRIPTIONS 1-2 P ................6 OWER UPPLY AND OWER ONSUMPTION 1-3 K ......................
  • Page 4 ZERO display . Press MC key to show firmware version 03005 (H4 series) or 03006 (X series). Press MC key again to show maintenance number XXX ranged from 000~999. Turn off and turn on scale to return to weighing mode.
  • Page 5: Precautions For Use

    When the low power warning symbol flashes, If not charge immediately, auto shut-down within 5~10 hours or 1~2 hours with backlight for H4 series. For X series, it auto shut-down within 8~12 hours or 3~6 hours with backlight. Once it auto shut-down and enter the battery protection mode, it must be charged before it can be used.
  • Page 6 EXCELL PRECISION CO., LTD. Lead-Acid Battery Notice Lead-acid battery adopts the advanced free-maintaining technique, customers need not to replenish electrolyte. The scale should be recharged every 3 months to battery over-discharged and shorten the life of the battery. 1. The battery should be fully charged for 8~10 hours.
  • Page 7: Chapter 1 Display And Keypad Descriptions

    EXCELL PRECISION CO., LTD. Chapter 1 Display and Keypad Descriptions 1-1 Display Descriptions Non-approval models: or resolution equal to 1 / 3,000 WEIGHT UNIT WEIGHT QUANTITY   +      stable  Approval models: and resolution equal to 1 / 3,000...
  • Page 8: Power Supply And Power Consumption

    EXCELL PRECISION CO., LTD. 1-2 Power Supply and Power Consumption 100~240Vac, 50/60Hz H4 series X series Software version 03005XXX 03006XXX Battery 6V / 4Ah lead acid battery 3.7V / 6100mAh Li battery Consumption 33mA / 0.20W 27mA / 0.11W (without backlight)
  • Page 9: Error Messages

    EXCELL PRECISION CO., LTD. Key Function Number key for setting the unit weight, quantity and etc. Clear key to clear the digits on the display. Unit weight key for setting the unit weight of sample. Press this key, the display returns to 0.
  • Page 10: Chapter 2 Operation

    EXCELL PRECISION CO., LTD. Chapter 2 Operation 2-1 Power On SW switch on (Press SW to location “ ”) WEIGHT UNIT WEIGHT QUANTITY After stable, the scale will count back to zero. WEIGHT UNIT WEIGHT QUANTITY 600 ⇒ Maximum countable data: 600 000 Sampling Speed After return to zero and being stable, scale will enter into counting mode.
  • Page 11: Enter Known Unit Weight

    EXCELL PRECISION CO., LTD. 3. Press key while total column number is flashing SAMPLE Weight on platter 4. After stable, the scale finishes sampling and enters into counting mode stable  Weight on platter Unit weight of object Enter sampling quantity 2-4-2 Enter Known Unit Weight 1.
  • Page 12: Tare Function Operation

    EXCELL PRECISION CO., LTD. 2-5 Tare Function Operation 1. Place the packaging container on platter Weight of packaging container 2. Press TARE 3. The scale will enter into counting mode after stable     stable  Clear off the tare value Mode 1: After removing the object together with packaging container, weight column will display the negative value of packaging container.
  • Page 13: Accumulation

    EXCELL PRECISION CO., LTD. 3. Press TARE   stable  Weight of the object without container Unit weight of the object Quantity without packaging container  Pre-Tare function is also available even if tare is in operation.  If the net weight on platter is more than zero weight, the tare function is available. Otherwise, it’s not capable of tare function.
  • Page 14: Weight Accumulation

    EXCELL PRECISION CO., LTD. Recall quantity accumulation While weight column displays 0, press key to recall the accumulated data  +    stable  Accumulated total weight Accumulated total counts Accumulated total quantity Clear off the accumulated quantity value...
  • Page 15: Weight Preset

    EXCELL PRECISION CO., LTD. 2. Enter the upper limit intended (Press key to modify the value entered)    stable  Upper limit entered 3. Press key (Press key to modify the value entered) SAMPLE    stable ...
  • Page 16: Id Input

    EXCELL PRECISION CO., LTD. 2-10 ID Input key, and the screen displays “- - - - - -”. Press Press key before it disappears. ZERO ID could be set up to 12 digits. They can be numbers (0~9), Enter ID with number keys English letters (A~Z), or ...
  • Page 17: Pre-Set Unit Weight Saving Operation (Read-Out)

    EXCELL PRECISION CO., LTD. Press key again U.W. PST Press number keys to select 1 of 50 addresses for saving the data. If it is over 50, Please re-enter. Press U.W. PST 2-12-2 Pre-set Unit Weight Saving Operation (Read-out) Press key again U.W.
  • Page 18: External Function Setting

    EXCELL PRECISION CO., LTD. 3-1 External Function Setting Press Enter parameter 00~13 After entering parameter 00, press key to return to previous level   “Zero” track range Return to previous level   Backlight mode setting Accumulation ending mode ...
  • Page 19: Auto. Power-Off Setting

    EXCELL PRECISION CO., LTD. 3-1-2 Auto. Power-off Setting Press key and enter parameter 00~10. Then press key to save the setting. Default Setting: 00; up to 10 minutes at most. 00  Auto Power-off function is off. 01~10  Scale is automatically powered off after not in use for 1~10 minutes.
  • Page 20: Accumulation Ending Mode Setting

    EXCELL PRECISION CO., LTD. 3-1-8 Accumulation Ending Mode Setting Press key and enter parameter 00~02. Then press key to save the setting. Default Setting: 00 00  Press key. Displays accumulation for 3 seconds, and return to weighing mode. 01  Press key.
  • Page 21: External Weight Andg Value Calibration

    EXCELL PRECISION CO., LTD. 3-2 External Weight and G Value Calibration EC 00  Return to previous level EC 01  External weight calibration Press EC 02  Calibrate G value used in local or in verification  Approval model (CFn 01 = 02~04) do not have Enter parameter 00~03 02 EC.
  • Page 22: Calibrate G Value Used In Local Or In Verification

    EXCELL PRECISION CO., LTD. 3-2-2 Calibrate G Value Used in Local or in Verification  It is capable for users to set or modify G value for 9 times. If it is the 10 revised G value, please enter “06 CGr” to calibrate local G value, and the calibration time will be re-set as “1”.
  • Page 23: Rs-232 And Serial Printer Setting

    EXCELL PRECISION CO., LTD. 3-3 RS-232 and Serial Printer Setting r S 1 00  Return to previous level r S 1 01  Baud rate setting Press r S 1 02  Communication protocol setting r S 1 03 ...
  • Page 24: Continuous Output Count Setting Per-Second

    EXCELL PRECISION CO., LTD.  Please see “Appendix 1” for output format. Fixed format is described as following: Fixed format 2 “Press Fixed format 1 “Press M+ key to print” key to print” xxxxxxx xxxxx ITEM: xxxxxxx xxxxx 2.480 2.480 2.000...
  • Page 25: Operation Mode Setting

    EXCELL PRECISION CO., LTD.  If parameter in rS1 03 is set as 02, it is not capable of continuous transmission mode.  If parameter in rS1 03 is set as 03 ~ 07, it is capable of continuous transmission mode.
  • Page 26: Continuous Transmission Output Condition Setting

    EXCELL PRECISION CO., LTD. 2. Press key to print “ “ <LF> <LF> <LF> <LF> <LF> <LF> <LF> TN: Total number TW: Total weights TA: Total quantities tn: Total number tw: Total weights ta: Total quantities NOTE: Fill in zero “0” for the blanks on the left.
  • Page 27: Weight Band Setting For Auto. Transmission

    EXCELL PRECISION CO., LTD. 3-3-8 Weight Band Setting for Auto. Transmission Press key and enter parameter 00~99. Then press key to save the setting. Default Setting: 05 (External value “5d”) 00  External value “0d” 01  External value “1d”...
  • Page 28 EXCELL PRECISION CO., LTD. and return value is 255. Command Format C According to the command format to modify ID,ITEM ,PT, UW : CR LF ITEM: CR LF CR LF CR LF Description: 1. 2 previous code is command code (must be capital letter),A is 0-9 or A-Z. Other symbol is unacceptable (because it can’t be showed on LCD).
  • Page 29: Appendix 2 Fixed Format Rs-232 Transmission Line Description

    EXCELL PRECISION CO., LTD. Simple Format (Price Computing, Counting, Weighing) Gross weight Net weight Tare Pre-tare + overload - overload Unstable Quantity Unit weight Accumulated counts PLU# Totally 11 bytes (including CR LF) Simple Accumulation Format Accumulated weight Accumulated quantity...
  • Page 30: Appendix 3 Ascii Code Table

    EXCELL PRECISION CO., LTD. Appendix 3 ASCII Code Table ASCII 30H ASCII 41H ASCII 4CH ASCII 57H ASCII 68H  ASCII 73H Appendix 4 7-Segment Display Characters 03005XXX/03006XXX ZSME200000060...

This manual is also suitable for:

X series

Table of Contents