Charger Error Codes - Terex Genie Z-60 DC Service Manual

Hide thumbs Also See for Genie Z-60 DC:
Table of Contents

Advertisement

August 2022

Charger Error Codes

Charg er Er ror Cod es
Charger Error
Genie
Genie
Code
Fault ID
Fault
Type
E-0-0-1
131
E-0-0-2
131
E-0-0-3
135
E-0-0-4
204
E-0-0-7
264
Part No. 1307785GT
Description
23
High battery voltage
24
Low battery voltage
detected prior to starting
charge cycle
28
Charge timeout
21
Defective battery
23
Amp hour limit exceeded
Z
®
-60 DC • Z
Charger Fault Codes
Condition
Battery voltage too high to
charge.
Battery voltage too low to
charge.
Charge timeout caused by
battery pack not reaching
required voltage within
safe time limit.
Battery pack could not be
trickle charged up to the
minimum voltage.
Safety limit exceeded.
®
-60 FE
Service and Repair Manual
Possible Causes
Check battery voltage and cable
connections.
Self clearing when condition has
been corrected.
Check battery voltage and cable
connections.
Check battery condition.
Self clearing when condition has
been corrected.
Charge output reduced due to
high temperature. Charge at lower
temperature.
Check battery condition.
Replace damaged battery.
Check battery connections.
Battery pack deep discharge.
Disconnect battery pack for
30 seconds to clear fault when
condition has been corrected.
Check battery condition.
Replace damaged battery.
Check battery connections.
Disconnect battery pack for
30 seconds to clear fault when
condition has been corrected.
Check battery condition.
Replace damaged battery.
Check battery connections.
Battery pack deep discharge.
High parasitic loads on battery
pack while charging.
Disconnect parasitic loads.
Disconnect battery pack for
30 seconds to clear fault when
condition has been corrected.
93