Charger Error Codes - Terex Genie S-60 FE Service And Repair Manual

Hide thumbs Also See for Genie S-60 FE:
Table of Contents

Advertisement

Service and Repair Manual
Charger Fault Codes

Charger Error Codes

Charger Error Codes
Description
Error Code
E-0-0-1
High battery voltage Battery voltage too high to
E-0-0-2
Low battery voltage
detected prior to
starting charge
cycle
E-0-0-3
Charge timeout
E-0-0-4
Defective battery
E-0-0-7
Amp hour limit
exceeded
90
Condition
charge.
Battery voltage too low to
charge.
Charge timeout caused by
battery pack not reaching
required voltage within safe
time limit.
Battery pack could not be
trickle charged up to the
minimum voltage.
Safety limit exceeded.
S
®
-60 DC • S
Possible Causes
Check battery voltage and cable connections.
Self clearing when condition has been
corrected.
Check battery voltage and cable connections.
Check battery condition.
Self clearing when condition has been
corrected.
Charge output reduced due to high temperature.
Charge at lower temperature.
Check battery condition.
Replace damaged battery.
Check battery connections.
Battery pack deep discharge.
Disconnect battery pack for 30 seconds to clear
fault when condition has been corrected.
Check battery condition.
Replace damaged battery.
Check battery connections.
Disconnect battery pack for 30 seconds to clear
fault when condition has been corrected.
Check battery condition.
Replace damaged battery.
Check battery connections.
Battery pack deep discharge.
High parasitic loads on battery pack while
charging.
Disconnect parasitic loads.
Disconnect battery pack for 30 seconds to clear
fault when condition has been corrected.
®
-60 FE
July 2021
Part No. 1299608GT