Agilent Technologies 8510C Configuration Manual page 9

Network analyzer family 45 mhz to 110 ghz

Advertisement

Verification kits
Verification kits are used to verify the performance
specifications of an Agilent 8510 system. All kits
include a precision Z
o
and fixed attenuators. Measured data and uncer-
tainties traceable to the U.S. National Institute of
Standards and Technology (NIST) are included
with each kit. Compliance with MIL-STD 45662A is
available for an extra charge (Option 1BP). Option
002 provides verification kit data on magnetic tape
for use with the 8510A/B.
Choose a verification kit for each connector type required.
Verification kit
Connector type
85051B
7 mm
85053B
3.5 mm
85055A
Type-N
85057B
2.4 mm
R11645A
WR-28
Q11645A
WR-22
U11645A
WR-19
V11645A
WR-15
W11645A
WR-10
Test port cables and adapters
Test port cables and adapter sets are available for
various connector types. Special test port adapter
sets convert the rugged ports of the network ana-
lyzer test set to the desired connector interface.
Each kit contains two adapters, one male and one
female. Both the cables and the test port adapters
have one special female connector which is
designed to connect directly to the 3.5 mm test
port (2.4 mm for 8517B). This side of the cable or
adapter can only be connected to the test set port
and cannot be mated to a standard 3.5 mm (or
2.4 mm) male connector. Choose one of the config-
urations shown.
airline, mismatched airline,
Frequency range (GHz)
0.045 to 18
0.045 to 26.5
0.045 to 18
0.045 to 50
26.5 to 40
33 to 50
40 to 60
50 to 75
75 to 110
Configuration A. This cable arrangement is for appli-
cations where the device under test is connected
directly to the test set port. This setup offers the
best mechanical rigidity for device connection. To
adapt the test set port (port 1) to the device under
test, choose the appropriate special adapter set. In
addition to converting the test port to the desired
interface, these adapters also function as "test port
savers" which protect the test set from damage and
wear due to heavy use.
For Agilent 8514B/8515A/85110A test sets
(3.5 mm rugged test port connectors)
Cables/adapters
For 3.5 mm
85131C semi-rigid cable or
devices
85131E flexible cable
85130D adapter set
For 7 mm
85132C semi-rigid cable or
devices
85132E flexible cable
85130B adapter set
For Type-N
Use 7 mm cables and the 7-mm-
devices
to-Type-N adapters included
in the 85054B/D Type-N
calibration kit
For Agilent 8517B test sets
(2.4 mm rugged test port connectors)
Cables/adapters
For 2.4 mm
85133C semi-rigid cable or
devices
85133E flexible cable
85130G adapter set
For 3.5 mm
85134C semi-rigid cable or
devices
85134E flexible cable
85130F adapter set
For 7 mm
85135C semi-rigid cable or
devices
85135E flexible cable
85130E adapter set
CONFIGURATION A
network analyzer
test set
test port
adapter
device
under
test
single cable
Connector type
(on device side of
cable/adapter)
3.5 mm (f)
3.5 mm (f )
3.5 mm (m and f)
7 mm
7 mm
7 mm
Connector type
(on device side
of cable/adapter)
2.4 mm (f)
2.4 mm (f )
2.4 mm (m and f)
3.5 mm (f)
3.5 mm (f )
3.5 mm (m and f)
7 mm
7 mm
7 mm
9