Download Print this page

System Components - Agilent Technologies 8510C Configuration Manual

Network analyzer family 45 mhz to 110 ghz

Advertisement

System components

For flexibility in specifying a solution that meets
your exact needs, a system can be ordered as sepa-
rate line items. A complete system includes the
Agilent 8510C network analyzer, a test set, compat-
ible source, and measurement accessories.
All major system components (network analyzer,
test sets, and sources) include one-year on-site
service.
8510C ATO options
• 8510C-008 Pulsed-RF capability requiring 85110A
or 85110L S-parameter test set
• 8510C-010 Add time domain
Rack flange kits
• 8510C-908 Rack flange kit, front handles detached
• 8510C-913 Rack flange kit, front handles attached
Additional documentation
• 8510C-910 Extra operating and service manual
set
• 8510C-916 Extra operating and programming
manual set
Extended service options are available.
Test set options
Option
Description
STD
No IF switching
001
Add IF switching for multiple test set operation
002
Delete step attenuators and bias tees
003
High forward dynamic range configuration
(degrades reverse transmission dynamic range)
003
Add attenuators and bias tees
999
Standard input power
004
High power configuration (moves port 2
attenuator in front of b2 sampler)
004
Add attenuators and bias tees
027
High source power
908
Add rack flange kit
913
Add rack flange and handles kit
910
Extra operating and service manual
Test sets (Choose one)
• 8514B S-parameter test set (45 MHz to 20 GHz)
With rugged 3.5 mm connector test ports
• 8515A S-parameter test set (45 MHz to 26.5 GHz)
With rugged 3.5 mm connector test ports
• 8517B S-parameter test set (45 MHz to 50 GHz)
With rugged 2.4 mm connector test ports
• 85110A pulsed-RF S-parameter test set (2 to 20 GHz)
For use with 8510C Option 008. Includes rugged
3.5 mm connector test ports and four built-in
step attenuators to independently set power
level to all four downconverter channels.
Requires 8360 series synthesized sources for
complete operation (83622B and 83623L).
• 85110L pulsed-RF S-parameter test set (45 MHz to
2 GHz)
For use with 8510C Option 008. Includes rugged
7 mm connector test ports and four built-in step
attenuators to independently set power level to
all four downconverter channels. Requires two
8360 series synthesized sources for complete
operation (83620B-H80, two each).
• 8511A frequency converter (45 MHz to 26.5 GHz)
3.5 mm connector ports
• 8511B frequency converter (45 MHz to 50 GHz)
2.4 mm connector ports
Note: Agilent 8511A/B require external, customer-
furnished couplers, or signal separating devices to
provide complete test set capability. A source with
front panel RF power output may be more suitable
for 8511-based applications.
8514B
8515A
8517B
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
85110A
85110L
8511A/B
X
X
X
X
X
X