Main Control Panel - Generac Power Systems MAGNUM MLT4250 Owner's Manual

Light tower
Table of Contents

Advertisement

Main Control Panel

K
(A) Receptacle Panel Main Circuit Breaker (100A)
This breaker disconnects power to the receptacle panel.
(B) Individual Circuit Breaker
One breaker is supplied for each light.
(C) Ballast Indicator Lights
Indicates power from the ballast to each light.
(D) Engine Control Panel
Refer to
Magnum Digital Controller (MDC) Features
and
Functions.
(E) Lug Door Safety Switches
These switches will shut down the unit if the lug door is
opened when the unit is running.
(F) Voltage Selector Switch
This switch will change the generator output between
three phase and single phase power. For more
information, refer to
Voltage Selector
Owner's Manual for MLT Light Tower
A
E
J
Figure 2-4. Control Panel
Switch.
C
B
(G) Cable Access
Allows for entry of load cables to the connection lugs with
the lug box door closed.
(H) Remote Start Terminal Block
Allows connections for remote starting of the unit.
(I) Generator Ground Connection Lug
This is for connecting a good earthen ground per the
National Electrical Code (NEC), state, and local
regulations before starting the unit.
(J) Generator Output Connection Lugs
These allow appropriate loads to be wired directly to the
generator.
(K) Main Circuit Breaker (90A)
This breaker will disconnect power to the connection
lugs.