Control Panel—MLT4060MV, MLT4060KV
K
J
I
(A) Main Circuit Breaker
This 240V (30A) breaker will disconnect power to the
lights and auxiliary outlets. It will also disable the starting
circuit if engine starting is attempted when the main
breaker is on.
(B) Light Switch (4 Locations)
One circuit breaker is supplied for each light.
(C) Ballast Indicator Light (4 Locations)
Indicates power from the ballast to each light.
(D) Engine Starting Switch
Keyed switch operates glow plugs, starts and stops
engine.
(E) Glow Plug Indicator (if equipped)
Indicates operation of the engine glow plugs (Mitsubishi
engines only).
(F) Engine Hour Meter
Keeps track of engine hours for service.
Owner's Manual for Mobile Light Tower
A
MAIN
BREAKER
240V
ON
ON
TURN
MAIN
BREAKER
OFF
120V
BREAKER
120V
Figure 2-4. Control Panel
B
C
BALLAST INDICATOR LIGHTS
I
I
I
ON
ON
ON
O
O
O
MAST LIGHT SWITCHES
OFF
GLOW
PLUG
240V
NEUTRAL BONDED TO FRAME
H
(G) DC Circuit Breaker
Circuit breaker (10A) for the engine electrical system.
(H) 240V Twist-Lock Outlet
This 240V (30A) outlet supplies power for accessories
connected to the generator when the engine is running
and the main circuit breaker is switched ON (I).
(I) 120V GFCI Outlets
This 120V (20A) GFCI outlet supplies power for
accessories connected to the generator when the engine
is running and the main circuit breaker is switched ON (I).
(J) 120V Breaker
This 120V (20A) circuit breaker is supplied for the 120V
GFCI duplex outlets.
(K) Circuit Breaker Indicator Light
This light indicates that the main circuit breaker must be
opened (switched off) before starting the engine.
General Information
I
ON
O
GLOW PLUG
RUN
INDICATOR
START
DC
BREAKER
D
E
F
G
009003
11