MAIN CONTROL PANEL - MLT3060MV, MLT3060KV

11
TURN
MAIN
BREAKER
OFF
10
120V
BREAKER
9
120V
8
1. MAIN CIRCUIT BREAKER: This 240V (30A) breaker will disconnect power to the lights and control panel
receptacles.
2. LIGHT SWITCHES: One circuit breaker is supplied for each light.
3. BALLAST INDICATOR LIGHTS: Indicates power from the ballast to each light.
4. ENGINE START SWITCH: Keyed switch operates glow plugs, starts and stops engine.
5. GLOW PLUG INDICATOR: Indicates operation of the engine glow plugs (Mitsubishi engines only).
6. ENGINE HOUR METER: Keeps track of engine hours for service.
7. DC BREAKER: Circuit breaker (10A) for the engine electrical system.
8. 120V DUPLEX RECEPTACLE: This unit is equipped with one 120V (20A) GFCI receptacle to supply power for
accessories connected to the generator when the engine is running and the main circuit breaker is switched "ON/I".
9. 240V TWIST-LOCK RECEPTACLE: This 240V (30A) receptacle supplies power for accessories connected to
the generator when the engine is running and the main circuit breaker is switched to the "ON/I" position.
10. 120V BREAKER: This 120V (20A) circuit breaker is supplied for the 120V GFCI duplex receptacle.
11. CIRCUIT BREAKER INDICATOR LIGHT: This light indicates that the main circuit breaker must be opened
(switched off) before starting the engine.
16
1
BALLAST INDICATOR LIGHTS
MAIN
BREAKER
240V
I
I
ON
ON
ON
ON
O
O
MAST LIGHT SWITCHES
240V
NEUTRAL BONDED TO FRAME
2
3
I
I
ON
ON
O
O
OFF
GLOW PLUG
GLOW
RUN
INDICATOR
PLUG
START
DC
BREAKER
4
5
6
7