Check Oil Level
Check Coolant Level
Check Fuel Level
Drain Fuel Filter
Check Tire Pressure
Check All Electrical Connections
Clean Battery
Check Fan Belt Tension (Replace If Necessary)
Inspect Radiator Fins For Debris, Clean As Required
Preheating Condition Check
Check Engine Starting Conditions And Noise Conditions
Check Exhaust Smoke Condition
Inspect Light Tower Winch For Proper Operation
Replace Engine Oil
Replace Fuel Filter Element
Clean Water Sedimenter Element
Electromagnetic Pump Filter Replacement or Cleaning
Check Fan Belt Tension (Replace If Necessary)
Oil Filter Element Replacement
Replace Air Filter Element
Lubricate Leveling Jacks
Replace Heated Fuel Filter (If Equipped)
Inspect Engine Starting Battery
Resetting the "Time to Service"
Reminder
The Magnum Digital Controller (MDC) will display
"WrnMaintenance" when the unit is due for maintenance
or service. The maintenance or service interval is set at
250 hours of engine running time. Once the unit has
been serviced, the Time to Service reminder needs to be
reset to the 250 hour interval. The following procedure
demonstrates how to reset the running hours to 250:
With the unit shut down, power up the controller
1.
with the Control Power switch. The Initialization
screen will be displayed. The controller will toggle
automatically to the Ready display screen.
Press the PAGE SELECT button. The next screen
2.
will display lines of text; starting with Password,
which will have a (>) in front of it, then Basic
settings, Engine params, Engine protect, etc.
Press the  button to move the (>) cursor down to
3.
"Engine protect."
Owner's Manual for MLT Light Tower
Table 4-1. Basic Maintenance Guide (Isuzu)
Item
Daily
Figure 4-2. Resetting Service Reminders
4.
Press ENTER. "WrnMaintenance" will appear at
5.
the top left of the display screen. The current
service time hour setting (0) will be one line below
it on the right side.
Press ENTER. The current run time in hours will
6.
now appear on the left side of the display screen,
directly under "WrnMaintenance."
Press  and reset the current run time hour setting
7.
to 250. If you pass the 250 time interval, use to
get back to the 250 time interval.
Maintenance
250
500
1000
Hours
Hours
Hours
004527