IMPORTANT !
PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE.
Note: When servicing the wall oven, Health and Safety issues must be considered at all times. Specific
safety issues are listed below with their appropriate icon. These are illustrated throughout the service
information to remind service people of the Health and Safety issues.
1.1.1 Electrical Safety
Ensure the mains power has been disconnected before servicing the wall oven. If the mains
supply is required to be on to service the wall oven, make sure it is turned off when
removing any electrical component or connection to avoid electric shock.
1.1.2 Electrostatic Discharge
An anti-static strap is to be used as electrical static discharge (ESD) protection when
servicing electronic components.
1.1.3 Good Working Practices
Ensure the work area is in a tidy and orderly condition at all times so as not to cause a
hazard while service work is being completed. Always clean and tidy the wall oven and
work area after service is completed.
1.1.3 Insulation Test
Megger test to check insulation.
Warning: Short together the phase and neutral pins on the plug so as not to damage any
electronic circuitry.
1.1.4 Sheet Metal Edges
When working around cut sheet metal edges use appropriate gloves or protection to
eliminate the chance of receiving a laceration.
1.1.5 Diagnostics
While in diagnostics some safety devices are bypassed. Ensure you do not run
components unattended.
D
1.2 Specialised Tools
For servicing this product, specialised tools are required.
1.2.1 Static Strap
To be used as ESD (electrostatic discharge) protection when replacing or handling electronic
components.