4.15 Power Transformer

Input Voltage:
120 VAC
Output Voltage:
12 VAC
4.16 Thermal Limiter
These products have manually resettable thermal
limiters.
Single ovens have one thermal limiter below the cooling
fan. Limiter is mounted on a bracket with spacers
underneath.
Double ovens have three thermal limiters, one for the
upper cavity and two for the lower cavity in series. On
the lower cavity, one limiter is mounted on a bracket
with spacers below the cooling fan; the other limiter is
mounted on the vent channel.
A thermal limiter will cut off power to the elements/
product, if it senses any malfunction in the cooling
system (see table below). When a limiter is tripped
"open", the reset button (orange tab) on the body will
be sticking out and there will be no continuity across its
contacts. The reset button needs to be pushed back to
reset the limiter.
If a limiter is found to be open, the root cause of the
tripping needs to be diagnosed and repaired. Refer to
Section 7.14, Tracing Limiter Faults (pg. 46).
All limiters used on these models are identical.
Capacity Rating:
16 Amps at 250 VAC
Trip Temperature: 284°F (140°C)
Product
Tripped Limiter
Single cavity
Only one limiter
products
Double cavity
Top cavity limiter
products
Lower cavity
Middle limiter
connected to
lower cavity limiter
in series
60hz
Outcome
Takes out power
to the elements
only
Takes out power
for the full
product
Takes out power
limiter
to the lower
cavity elements
Reset
Button
17