I Scan Edges Programming - Icom IC-V8000 Instruction Manual

Icom ic-v8000: instruction manual
Hide thumbs Also See for IC-V8000:
Table of Contents

Advertisement

7
SCAN OPERATION

I Scan edges programming

Scan edges can be programmed in the same manner as
memory channels. Scan edges are programmed into scan
edges, 1A/1b to 3A/3b, in memory channels.
q Set the edge frequency of the desired frequency range in
VFO mode:
➥ Set the frequency using the tuning dial.
➥ Set other data (e.g. repeater settings, etc.) if desired.
w Push [MW(S.MW)] momentarily.
• "M" indicator and channel number blink.
e Rotate the tuning dial to select one of scan edge channel,
1A, 2A or 3A.
[EXAMPLE]: Programming 145.300 MHz into scan edges 1A.
Rotate
for setting frequency, etc.
39
Push
Push
MW
for 1 sec. and continue to push
S.MW
"
"
Beep
"
Beep
"
Beep
"
r Push [MW(S.MW)] for 1 sec. to program.
• 3 beeps sound and VFO is automatically selected.
• Scan edge 1b, 2b or 3b is automatically selected when continu-
ing to push [MW(S.MW)] after programming.
t To program a frequency for the other pair of scan edges,
1b, 2b or 3b, repeat steps q and r.
• If the same frequency is programmed into a pair of scan edges,
programmed scan will not function.
MW
momentarily.
Rotate
S.MW
"
Beep

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents