6-2
S
ERVICE
7. Replace fan motor. Make certain harnesses are
not caught or otherwise damaged. Replace
screws.
8. Replace gasket, fan blade, and nut.
9. Position fan assembly in plenum and reattach
with 6 screws. Reconnect fan motor to wiring
harness. Turn on power.
10. Verify that fan motor is working and fan blade
is turning in the correct direction.
Make sure fan blade spins freely.
F2XLG
Reheat Heater
Anti-Sweat Heater
Electric Defrost
Thermostat
Multiglass with
Anti-Sweat Heater
Refrigeration Thermostat
Anti-Sweat Heater
P/N 424382A
!
Always disconnect the electrical power at the
main disconnect when servicing or replacing
any electrical component. This includes, but
is not limited to, such items as fans, heaters,
thermostats and lights.
Ambient
Ballast
Muffin
Fans
WARNING
Defrost
Fluorescent Lamps
Heater
Reheat Heater
Heater Limit
Thermostat
Evaporator
Fans