Graco Aerobotix RC50 Instructions Manual page 24

Table of Contents

Advertisement

Operation
Temperature Control Screen
FC
FA
F
. 11
IG
Key:
FA Ideal Temperature Setpoint
FB High Temperature Alarm Setpoint
FC Low Temperature Alarm Setpoint
Heat Exchange and Supply Heater Temperature
Control
These buttons are used to turn temperature control on
or off. When a metering pump motor is on and the asso-
ciated temperature control is on the indicator below will
indicate ON and when it is off it will indicate OFF. When
temperature control is on but the associated metering
pump motor is off, the indicator below will show "Permit-
ted". If the temperature control is off for any reason, the
indicator will display "not permitted" to show that the
temperature control will not turn on when the metering
pump motor is turned on.
See Temperature Gains on page 46.
24
1
Press the Temp Gain Setup button to change the temperature
gains.
FB
FD Actual Temperatures
FE Temperature Log Access
FF Temperature Gain Access
FD
FE
FF
1
313813A