Manual Control Screen
DA
DB
F
. 8
IG
Service Mode
Service mode allows the operator to open the gun for
service under no load. The Open/Close Service Mode
Gun Control buttons will not be active unless the Service
Mode button is pressed. The Service Mode button shuts
both pumps down to eliminate the chance of material
being dispensed while the gun is being serviced.NOTE:
The gun may still dispense material because of the
pressure on the day tanks. Ensure that the gun is also in
service mode to prevent this from occurring.
Manual Mode Gun Control
The Manual Mode Gun Control allows the operator to
dispense material manually from the HMI. The material
will dispense for the duration of time assigned to the
channel set. The time duration can be set for each chan-
nel under the Pour Time Editor.
313813A
DE
DC
1
Only active when service mode has been selected.
Key:
DA Visual Indicators: PLC Inputs
DB Visual Indicators: PLC Outputs
DC Temperature/Flow Information
DD Visual Indicator of Active Gun
DE Service Mode Control
DD
1
Automatic Mode Status
The Automatic Mode Status section is a visual status
indicator for the communication between the RC
machine and the Robot. The machine must be in Auto
Mode for the indicators to function. If the RC machine
receives a signal from the robot while in Manual mode,
the indicator will show the signal, but the signal will be
ignored. For further detail on this interface, refer to the
Robot Interface section found in this manual.