System board and components
Ê Remove the TPM, see section

15.7.1.3 Installing the new system board

Ê Check the settings on the new system board (see section
settings" on page
Ê Insert the system board by holding it at a slight angle. Slide the connectors
into the I/O panel (see figure
Ê Lower the system board carefully into the chassis.
Ê Adjust the system board. If necessary adjust the position of the system
board with a gentle twisting motion (orange circles in figure
show the centering bolts).
Ê Fasten the system board with the 13 screws (see figure
Ê For Japan / APAC / North America only:
Replace the CMOS battery installed on the new system board with a new
CMOS battery (see section
charging of CMOS battery might be reduced during stocked in warehouse.
Ê Remove the heat sink with the CPU from the defective system board, see
section
"Removing the heat sink" on page
Ê Remove the protective plastic cover from the CPU socket of the new system
board and fit it onto the socket of the defective system board which will be
sent back to spares.
I
Returned system boards without this cover probably have to be
scrapped.
Ê Install the heat sink with the CPU on the new system board, see section
"Installing the CPU and heat sink" on page
Ê Reconnect all cables to the system board:
– Front panel cable
– Front USB cable
– Power cable(s) for HDD backplane(s)
– SATA cable(s) for HDD backplane
– SATA cable for ODD (if applicable)
– Power cable for ODD (if applicable)
– OOB cable (if applicable)
I
For the cable plan, see chapter
384
"Removing the TPM" on page
406).
269 on page
"CMOS battery" on page
Upgrade and Maintenance Manual
383).
349), because
259.
253.
"Appendix B" on page
356.
"Onboard
269 on page 383
269 on page
383).
411.
RX2520 M4