41
start character match for Code 39, 41h = "A"
FF
termination string for first code
6A
code identifier for Code 128
0013
B - Code 128 sample length (12) plus CR suffix (1) = 13
42
start character match for Code 128, 42h = "B"
FF
termination string for second code
69
code identifier for Code 93
0012
C - Code 93 sample length (11) plus CR suffix (1) = 12
43
start character match for Code 93, 43h = "C"
FF
termination string for third code

Output Sequence Editor

Enter Sequence

Require Output Sequence

When an output sequence is Required , all output data must conform to an edited
sequence or the imager will not transmit the output data to the host device.
When it's On/Not Required , the imager will attempt to get the output data to
conform to an edited sequence, but if it cannot, the imager transmits all output
data to the host device as is.
When the output sequence is Off , the bar code data is output to the host as the
imager decodes it.
Note: This selection is unavailable when the Multiple Symbols Selection is
turned on.
Required
*Off
3 - 10
Default Sequence
On/Not Required
4800p 2D Imager User's Guide