Pioneer PDP-R05G Service Manual page 117

Table of Contents

Advertisement

5
2 FUNCTION CHECK
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
1
F U N C T
I O N
2
3
4
5
6
7
8
9
10
11
12
13
14
F A N
< = >
15
16
No.
Display
1
IC1 TEST
2
IC2 TEST
3
IC3 TEST
4
IC4 TEST
5
FAN <=>
6
AFT <=>
7
BSD ANT VOLT <=>
8
AUTO PRESET CHECK <=>
2.1 FAN
Controls FAN speed by force. (MIN : STOP, CNT : Low Speed, MAX : High)
Temp sensor is working only displaying data value in service factory mode.
After getting off service factory mode, this function is set to normal automatically.
2.2 AFT LOCK
For production line use only
Stop AFT tuner received function and receive a center frequency.
After turning off a unit (including stand-by mode), this setting is set normal (AFT function) automatically.
It's performed to two tuner and DTV tuner to U.S. model.
2.3 AUTO PRESET CHECK
For production line use only
Select No.
Display
1 (Default)
NO
7
YES
5
6
C H E C
K
V D 1 – 1 3 1 – N T V – J H S
: M I N
Detail
: MINI ⇔ CONT ⇔ MAX
UNLOCKED ⇔ LOCKED
15V ⇔ 11V ⇔ 0
NO ⇔ YES
Function
Perform AUTO PRESET function to specific frequency
to reduce AUTO RESET time at production line.
6
7
No last memory in this menu
Remarks
For CMX
For CMX
For CMX
For CMX
For Factory use
Only domestic model
Only Europe HD and for
Factory use
Performing this function when shifting from
"NO" to "YES".
PDP-R05G
7
8
232C Command
*1
ALN/ALY
BVH/BVM/BVL
None
Remarks
117
8
A
B
C
D
E
F

Advertisement

Table of Contents
loading

This manual is also suitable for:

TldpfrProvisional

Table of Contents