5-7. VU METER ADJUSTMENT

Conditions for adjustment
STEP-1
. Set the MIC/LINE 1 or MIC/LINE 2
knob on the front panel to the
scale "7" position.
STEP-2
5-4(E)
Specifications
LINE OUT (ORG) connector/rear panel
Output at the connector= _10 dB
VU meter/front panel
5
60
VU
Make adjustment so that the meter pointer stays at 0 VU.
Adjustment point
1 Level adjustment knob
MASTER / front panel