FUSE SPECIFICATIONS
The air conditioner's circuit board (PCB) is designed with a fuse to provide overcurrent protection.
NOTE
The specifications of the fuse are printed on the circuit board ,such as:
T3.15AL/250VAC, T5AL/250VAC, T3.15A/250VAC, T5A/250VAC, T20A/250VAC, T30A/250VAC,etc.
NOTE: For the units using R32 or R290 refrigerant , only the blast-proof ceramic fuse can be
used.
FLUORINATED GASES
This air-conditioning unit contains fluorinated greenhouse gases. For specific information on
NOTE
the type of gas and the amount, please refer to the relevant label on the appliance itself or the
"Operation Manual" in the packaging of the outdoor unit.
Installation, service, maintenance and repair of this unit must be performed by a certified
technician.
Product uninstallation and recycling must be performed by a certified technician.
For equipment that contains fluorinated greenhouse gases in quantities of 5 tonnes of CO
equivalent or more, but of less than 50 tonnes of CO
system installed, it must be checked for leaks at least every 24 months.
When the unit is checked for leaks, proper record-keeping of all checks is strongly recommended.