Rinnai P Series Installation Manual

Rinnai P Series Installation Manual

Split type wall mounted air conditioner
Hide thumbs Also See for P Series:

Advertisement

Quick Links

Models
System
Indoor
HSNRP26
HINRP26M
HSNRP35
HINRP35M
HSNRP50
HINRP50M
HSNRP60
HINRP60M
HSNRP70
HINRP70M
HSNRP80
HINRP80
HINRP20M
Ref Only
P Series Split Type Wall Mounted Air Conditioner
Installation Manual
Outdoor
HONRP26
HONRP35
HONRP50
HONRP60
HONRP70
HONRP80
Matching Multi System Only
REFRIGERANT
R32

Advertisement

Table of Contents
loading

Summary of Contents for Rinnai P Series

  • Page 1 Models REFRIGERANT System Indoor Outdoor HSNRP26 HINRP26M HONRP26 HSNRP35 HINRP35M HONRP35 HSNRP50 HINRP50M HONRP50 HSNRP60 HINRP60M HONRP60 HSNRP70 HINRP70M HONRP70 HSNRP80 HINRP80 HONRP80 HINRP20M Ref Only Matching Multi System Only P Series Split Type Wall Mounted Air Conditioner Installation Manual...
  • Page 2 OH&S requirements This appliance must be installed, maintained and removed only by an Authorised Person. For continued safety of this appliance it must be installed and maintained in accordance with the manufacturer’s instructions. REFRIGERANT Rinnai Split AC IM...
  • Page 3: Table Of Contents

    Preparations and Precautions �������������������������������������������������������������������������������������������������������������������������� 26 Evacuation Instructions ������������������������������������������������������������������������������������������������������������������������������������ 26 Note on Adding Refrigerant ������������������������������������������������������������������������������������������������������������������������������ 27 Electrical and Gas Leak Checks Before Test Run ������������������������������������������������������������������������������������������������������������������������������������������������ 28 Electrical Safety Checks ����������������������������������������������������������������������������������������������������������������������������������� 28 Test Run Test Run Checks ���������������������������������������������������������������������������������������������������������������������������������������������� 29 Checklist Contacts Rinnai Split AC IM...
  • Page 4: Warnings And Important Information

    For safety and warranty purposes, appliances that may be damaged or incorrect MUST NOT be installed or operated under any circumstances. Installation of damaged or incorrect appliances may contravene local government regulations. Rinnai disclaims any liability or responsibility whatsoever in relation to the installation or operation of damaged or incorrect appliances.
  • Page 5 Make sure to check for and rectify any refrigerant leaks after you install or repair the unit. This appliance uses R32 (difluoromethane) refrigerant, which is a flammable gas class 2.2 according to AS/NZS 1677 and must be handled by a refrigeration mechanic with appropriate Australian refrigerant handling licence. Rinnai Split AC IM...
  • Page 6 If the air conditioner is used together with burners or other heating devices, thoroughly ventilate the room to avoid oxygen deficiency. In certain functional environments, such as kitchens, server rooms, etc., the use of specially designed air-conditioning units is highly recommended. Rinnai Split AC IM...
  • Page 7 The table below indicates the temperature ranges the air conditioner can be operated within. MODE Cool Mode Heat Mode Dry Mode Room Temperature > 16°C < 30°C > 16°C Outdoor Temperature 0°C ~ 50°C -15°C ~ 24°C 0°C ~ 50°C Rinnai Split AC IM...
  • Page 8 10mA, the residual current device (RCD) having a rated residual operating current not exceeding 30mA, and disconnection must be incorporated in the fixed wiring in accordance with the wiring rules. Rinnai Split AC IM...
  • Page 9 If the system has a leak detection system installed, it must be checked for leaks at least every 24 months. When the unit is checked for leaks, proper record-keeping of all checks is strongly recommended. Rinnai Split AC IM...
  • Page 10: Accessories

    (if supplied ,please refer to the wiring diagram to install Varies by model it on the connective cable. ) Pass the belt through the hole of the Magnetic ring to fix it on the cable Page 16   Rinnai Split AC IM...
  • Page 11: Installation Summary

    Connect Piping Connect Wiring (not applicable for some locations in North America ) Wrap Piping and Cable Prepare Drain Hose (not applicable for some locations in North America ) STEP Mount Indoor Unit Rinnai Split AC IM  Page 17 ...
  • Page 12: Description

    Louver (Some Units) Refrigerant Piping NOTE ON ILLUSTRATIONS Illustrations in this manual are for explanatory purposes. The actual shape of your indoor unit may be slightly different. The actual shape shall prevail.  Page 18  Rinnai Split AC IM...
  • Page 13: Indoor Installation

    Then secure the mounting plate to the wall by tightening the screws directly into the clip anchors. Page 19   Rinnai Split AC IM  Page 19 ...
  • Page 14 Left rear wall hole Right rear wall hole 90mm (3.54in) 90mm (3.54in) Model E NOTE: When the gas side connective pipe is Φ 16mm(5/8in) or more, the wall hole should be 90mm(3.54in). Rinnai Split AC IM Page 20  ...
  • Page 15 To prevent unwanted leaks the unit. Any dents in the piping will affect you must plug the unused the unit’s performance. drain hole with the rubber plug provided. Rinnai Split AC IM Page 21  ...
  • Page 16 STRICTLY IN ACCORDANCE WITH THE PANEL. power, always wait 10 minutes or more before WIRING DIAGRAM LOCATED ON THE you touch the electrical components. ’ BACK OF THE INDOOR UNIT S FRONT PANEL . Rinnai Split AC IM Page 22  ...
  • Page 17 You need to access unit, and the plastic panel on the back. them to test for leaks at the end of the installation process (refer to Electrical Checks and Leak Checks section of this manual). Rinnai Split AC IM Page 23  ...
  • Page 18 Hook the top of the indoor unit on the upper hook of the mounting plate. Use a bracket or wedge to prop up the unit, giving you enough room to connect the refrigerant piping, signal cable, and drain hose. Rinnai Split AC IM Page 24  ...
  • Page 19: Outdoor Installation

    Mount the unit high enough to be above the average accumulated area snowfall. The minimum height must be 18 inches Rinnai Split AC IM Page 25  ...
  • Page 20 In cold climates, make sure that the drain hose is as vertical as possible to ensure swift water drainage. If water drains too slowly, it can freeze in the hose and flood the unit. Rinnai Split AC IM  Page 26...
  • Page 21 6. Carefully lift unit and place its mounting feet PROTECTION IS RECOMMENDED AT ALL on brackets. TIMES. 7. Bolt the unit firmly to the brackets. 8. If allowed, install the unit with rubber gaskets to reduce vibrations and noise. Rinnai Split AC IM Page 27  ...
  • Page 22 Please select the appropriate through-hole according 6. Using the cable clamp, fasten the cable to the to the diameter of the wire. unit. Screw the cable clamp down tightly. Page 28 Rinnai   Split AC IM...
  • Page 23: Refrigerant Piping Connection

    Be extra careful not to damage, dent, or deform the pipe while cutting. This will angle. deform the pipe while cutting. This will drastically reduce the heating efficiency drastically reduce the heating efficiency of the unit. of the unit. Page 29   Rinnai Split AC IM...
  • Page 24 Instructions for Connecting Piping to Indoor Unit Align the center of the two pipes that you will connect. Indoor unit tubing Flare nut Pipe Rinnai Split AC IM Page 30  ...
  • Page 25: Instructions For Connecting Pipe To Outdoor Unit

    Do not grip the nut that seals the service off other parts of valve. valve. Valve cover While firmly gripping the body of the valve, use a torque wrench to tighten the flare nut according to the correct torque values. Rinnai Split AC IM Page 31  ...
  • Page 26: Air Evacuation

    Wait for 5 minutes, then check that there has been no change in system pressure. Page 32   Rinnai Split AC IM Page 32  ...
  • Page 27: Note On Adding Refrigerant

    For R290 refrigerant unit, the total amount of refrigerant to be charged is no more than: 387g(<=9000Btu/h), 447g(>9000Btu/h and <=12000Btu/h), 547g(>12000Btu/h and <=18000Btu/h), 632g(>18000Btu/h and <=24000Btu/h). CAUTION mix refrigerant types. DO NOT Rinnai Split AC IM Page 33  ...
  • Page 28: Electrical And Gas Leak Checks

    B: High pressure stop valve locations in North America. C& D: Indoor unit flare nuts Note: This may not be required for some locations in North America.  Page 34   Page 34  Rinnai Split AC IM...
  • Page 29: Test Run

    All piping is properly insulated Perform Test Run as normal. Unit performs COOL function properly Unit performs HEAT function properly Indoor unit louvers rotate properly Manual control button Indoor unit responds to remote controller Page 35   Rinnai Split AC IM...
  • Page 30: Checklist

    No cooling or heating Is the end user fully aware of the operating procedure? Incorrect operation If you have answered no to any of the above, you must check and correct before appliance hand-over to customer. Rinnai Split AC IM...
  • Page 31 NOTES Rinnai Split AC IM...
  • Page 32: Contacts

    Help Line. Rinnai recommends that this appliance be serviced every 3 years. With our policy of continuous improvement, we reserve the right to change, or discontinue at any time, specifications or designs without notice. Rinnai Split AC P Series – IM – Issue 1 – July 2021...