WARNINGS AND IMPORTANT INFORMATION
INSTALLATION
This appliance shall be installed in accordance with local electrical safety regulations by an
WARNING
authorised person such as a licensed electrician. Contact an authorised service technician for
repair or maintenance of this appliance.
Only use the included accessories, parts, and specified parts for installation. Using non-standard
parts can cause water leakage, electrical shock, fire, and can cause the unit to fail.
Install the unit in a firm location that can support the unit's weight. If the chosen location cannot
support the unit's weight, or the installation is not done properly, the unit may drop and cause
serious injury and damage.
DO NOT turn on the power until all work has been completed.
When moving or relocating the air conditioner, consult experienced service technicians for
disconnection and reinstallation of the unit.
How to install the appliance to its support, please read the information for details in "indoor unit
installation" and "outdoor unit installation" sections.
For units that have an auxiliary electric heater, DO NOT install the unit within 1 meter (3 feet) of
any combustible materials.
DO NOT install the unit in a location that may be exposed to combustible gas leaks. If combustible
gas accumulates around the unit, it may cause fire.
Install drainage piping according to the instructions in this manual. Improper drainage may cause
water damage to your home and property.
This appliance is a Type 1 Electrical Appliance.
Make sure the live wire, neutral wire and earth wire in the power socket are properly connected.
Inadequate or incorrect electrical connections may cause fire or electric shock.
The yellow-green wire in air conditioner is the earthing wire which cannot be used for other
purposes. Improper earthing may cause electric shock.
The circuit breaker must have the functions of magnetic tripping and heat tripping to prevent
short circuit and overload.
Use a standard circuit breaker and fuse conforming with the rating of the appliances.
The unit must be earthed in accordance with local regulations.
Connect all wiring tightly. Failure to do so may result in electric shock or product failure.
DO NOT supply power to the unit until all wiring and tubing are completed.
Select an installation location where the components can be mounted securely and accessible
for service and replacement.
Make sure tubing is properly insulated to ensure optimum performance.
Install the drain hose properly for smooth drainage of condensed water.
Make sure to check for and rectify any refrigerant leaks after you install or repair the unit.
This appliance uses R32 (difluoromethane) refrigerant, which is a flammable gas class 2.2
according to AS/NZS 1677 and must be handled by a refrigeration mechanic with appropriate
Australian refrigerant handling licence.