  • Page 1 CE-150 CE-250 CE-350 Service Manual 104 72 85-26 14 Feb 2008...
  • Page 2: Table Of Contents

    Removing the circuit board cover .......................36 Removing control panel assembly......................37 Oiling in Shuttle area and Needle bar......................40 Remove the Hoop carrier cover........................41 Recognizing hoop size ..........................41 Adjustment origin position of embroidery foot along X & Y axis ..............42 Singer Furtura III series...
  • Page 3: Esd

    • Toutes les pièces moulées (en plastique) de nos produits sont marquées du nom du matériau utilisé, quand la taille de la pièce le permet. Singer Furtura III series...
  • Page 4: Service Tools

    5. Gauge for the needle height - 28.50 mm 6. Distance gauge 0.05-1,00 mm 7. Wrench 7 mm 8. Allen Key (hex driver) : 2 mm 9. Allen Key (hex driver) : 2.5 mm 10 Allen Key (hex driver) : 1.5 mm Singer Furtura III series...
  • Page 5: Needle Bar Height

    5. Check by means of a twin needle that the needle bar is not twisted, it may cause jump stitches when sewing with a twin needle. 6. Check to see if needle threader operates correctly NOTE! This setting affects: 2. Needle threader height 5. Feed-dog timing (vertical movement) 85005 12. Needle timing to shuttle Singer Furtura III series...
  • Page 6: Needle Threader Height

    6. Tighten the screw (B) . Make sure to attaching the threader stopper onto stopper pin (D). NOTE! The direction of threader stopper should be facing to the front so it does not hit the needle support bracket. Threader stopper Singer Furtura III series...
  • Page 7 Adjustment of threader hook sideways 1. If the sideways position of the hook isn’t correct, adjust the hook position with a small screw driver. 2. Recheck that the needle threader works correctly Singer Furtura III series...
  • Page 8: Presser Foot Height And Parallelism To The Needle Plate

    Loosen up set screw (A) and adjust the parallelity of the presser foot, by turn the Presser bar to the left or to the right. 7. Tighten the set screw (A) securely. 8. Re-check height and parallelity of the presser foot. Singer Furtura III series...
  • Page 9: Feed-Dog Height

    Turn clockwise : It will be higher Turn counter clockwise : It will be lower This Adjustment can be done, without remowning the covers, through the hole (B) on the front cover. 3. Re-check the feed dog height. Singer Furtura III series...
  • Page 10: Feed-Dog Timing (Vertical Movement)

    , the tip of needle must be fl ush with the surface of needle plate too (+/- 2 mm). 3. Tighten both screws fi rmelly after the adjustment. NOTE! After adjustment , be sure to check and/or adjust “Needle timing to shuttle” Singer Furtura III series...
  • Page 11: Feed Timing ( Horizontal Movement )

    7. Check so the feed dog movement is in the range of 0.3 to 0.6 mm, before the needle start to travel down from its upper turning position. 8. If wrong: Re-do from point 2. 9. If ok : Tighten the set screw (A) on the main shaft (B) fi rmelly. Needle at upper turning position 0.3-0.6 mm Singer Furtura III series...
  • Page 12: Positioning Of Pulse Motor For Feeding - Basic Point

    It is recommended to adjust feed pitch with stretch stitch patterns such as pattern #17. Note: Feed pitch for all stitch patterns can be adjusted with the screw A only. It is desirable to adjust feed pitch with most needed stitch pattern. Singer Furtura III series...
  • Page 13: Feed Balance

    - Turn the screw (B) counter clockwise to adjust forward stitch (F). Repeat the process until desired feed balance is obtained. 4. Tighten the nut (A) with a 7 mm wrench. 5. Re-check from point 1 in ”check of stitch balance” Singer Furtura III series...
  • Page 14: Basic Positioning Of Zigzag Step Motor

    12. Check so the circle mark (E) is in the position against the lifting cam (A). 13. Turn off the machine and tighten the seconded Set screw on the Step motor cogwheel (B). 14. Check the needle in centre position. 15. Check the Singer Furtura III series...
  • Page 15: Adjustment Of Needle At Center Position

    2. Break loose the 2mm hex set screw (A). 3. Turn eccentric screw (B) on needle bar until the needle is in the centre of the middle slots of needle plate, see illustation 1 4. Tighten the 2 mm hex set screw (A). Singer Furtura III series...
  • Page 16: Positioning Of Stopper For Needle At Right Position

    (A) should now be against the calibration stop (B). 3. Loosen up the screw (E) and move the stopper (C) untill the distance is 0.3 and 0.5 mm between stop- per (C) and the cam follower (D). 4. Tighten the screw 0.3-0.5 mm Singer Furtura III series...
  • Page 17: Tension Of Timing Belt

    - Too strong tension may result in incorrect operation due to increased machine torque. Adjustment 1. Loosen two screws(B) on support plate for idler pulley (A) 2. Move the position of idler pulley (A) ontil the correct belt tension is obtained. 3. Tighten the two screws (B). Singer Furtura III series...
  • Page 18: Needle Timing To Shuttle

    5. Move the position of gear so the distance between point below the shuttle hook and the upper side of the needle eye is 0.5-1.2 mm. 5. Temporarily tightened one the set screws and check so the distance is 0.5-1.2 mm. 6. Before tighten the screw, check the mesh of hook gears Singer Furtura III series...
  • Page 19: Mesh Of Shuttle Gears

    NOTE!When moving the lower shafts hook gear in any direction, the ”Needle timing to shuttle” will change. 3. Temporarily tightened one of the set screws and re-check ”Needle timing to hook”. 4. When both settings are correct , tighten the two set screws (B) fi rmelly. Singer Furtura III series...
  • Page 20 5. Tighten the set screw (A) and (B) fi rmly 6. Turn the hand wheel and check needle clearance to shuttle at both left and right sides of needle posi- tions is even. NOTE! This setting infl uences”16. Needle clearance to shuttle” Singer Furtura III series...
  • Page 21: Needle Clearance To Shuttle

    6. Tighten the set screw (A). 7. Re-check to see so the needle clearance to shuttle is within 0.05 to 0.15 mm. 0.05~0.15 mm 0.05~0.15 mm Right Zigzag position Left Zigzag position Hook Hook 0.05~0.15 mm Singer Furtura III series...
  • Page 22: Retaining Bracket For Bobbin Case

    5. Loosen screw (C) and adjust the position of reverse rotation stopper (F) so that there is a clearance of 1 to 1.5 mm between the projection and plate spring while turning the bobbin case back and forth. 6. Tighten the screw (C) securely. 1-1.5 mm Singer Furtura III series...
  • Page 23: The Lengthwise Movement Of The Feed Dog

    2. Loosen set screw (C) of feed regulating arm (B) on horizontal feed shaft (A) which operates feed dog. 3. Adjust the position by moving the feed dog theeth in either way. 4. Hold feed dog theeth in position with one fi nger then tighten the set screw (C) fi rmly. 0.5-1.5 mm Singer Furtura III series...
  • Page 24: Bobbin Case Thread Tension

    2. Pull the thread slowly and turn screw (A) until the correct thread tension is obtained. NOTE! Remove any loose pieces of thread or fl uff from the thread ten sion discs before any adjustment is done. Singer Furtura III series...
  • Page 25: Upper Thread Tension Unit

    4. Remove Thread tension dial (A) and re-set it so ”S” is in front of the index on the front cover. 5. Tighten cap screw (B). NOTE! Before any adjustment is done remove any loose pieces of thread or fl uff from the thread tension discs Singer Furtura III series...
  • Page 26: Position Of Buttonhole Sensor Lever

    2. Move the cantilever (B) to change the closing timing in either way. 3 Tighten screw (A). Buttonhole lever is at free position. Buttonhole lever is at position of A below Buttonhole lever is at position of B below Singer Furtura III series...
  • Page 27: Tension Of Motor And Pulley Belt

    NOTE! Too tight tension may result in abnormal rotation due to more burden on motor and more machine torque. On the contrary, too weak tension may result in noise from belt and slipping of belt. Pushing lightly (about 300 g) with finger Singer Furtura III series...
  • Page 28: The Needle Stop Position

    (E) and move the the controler board sensors (D) until the controler discs aren’t hitting the sensor. 6. Tighten the two (2 mm hex) screws (E). 7. Re check setting and tighten the two screw (A) fi rmelly. Singer Furtura III series...
  • Page 29: Function Mode Of Sewing Machine - Thread Sensor Deactivated

    In Functions mode when operating the embroidery mode of machine, it must be connect to a PC through a USB cable. To run the machine use start/stop switch after the embroidery data is transfered to machine from PC. CE-150 CE-250 and CE-350 Singer Furtura III series...
  • Page 30: Test Mode Of Sewing Machine - Apply To Model Ce-200E, Ce-250/350

    5. Release the reverse button and now should button Nr 1 blink. In case of embroidery sewing, enter the Embriodery unit before enter the test menu. ① ② ③ ④ ⑤ ⑥ Singer Furtura III series...
  • Page 31: Test Mode For Sewing Machine

    After entering mode 5 the upper rotary Thread break sensor is activated after 8 stitches and machine will stop Mode 6: Check spring sensor Machines should stops at 3 times by check-spring sensor activated while machines starts without thread. Singer Furtura III series...
  • Page 32: Test Mode For Sewing Machine With Embroidery Unit

    The machine will make a diamond shape continuously at 600 rpm. 4 5 6 The machine runs continuously under the test mode 6. Push the start/stop switch again and the machine will stop. Note! Circle mark is starting point in the picture. Singer Furtura III series...
  • Page 33: Removing Face, Bottom And Base Covers

    3. Remove the two screws (D) holding the support leg. Then remove the Support leg 3. Remove the screw (E), then remove the bottom cover 4. Remove four screws (F) on base cover. and then remove base cover. Singer Furtura III series...
  • Page 34: Removing Top Cover And Thread Sensor Cover

    Removing rear cover 1. The top, face, bottom and base covers must be removed fi rst. 2. Remove four screws (A,B and C). 3. For the free arms cover remove screw (C), use thin Phillips screw driver. Singer Furtura III series...
  • Page 35: Removing Front Cover

    3. Lay the machine on its back and remove two screws (B) from the bottom. 4. Pull out the front cover and disconnect the three cables (C) that connects the front cover to the main PC Board. Singer Furtura III series...
  • Page 36: Removing The Circuit Board Cover

    Removing the circuit board cover 1. Remove two screws (A). 2. Pull the Curcuit board cover straight out. The Circuit board is located inside of rear cover. Singer Furtura III series...
  • Page 37: Removing Control Panel Assembly

    4. Pull out the control panel from the front cover. Disconnect the 4 cables (B) from the control panel. Then remove the control panel. Note: When adjusting the machine with the front cover removed, connect the control panel assy. with the machine. Singer Furtura III series...
  • Page 38 Switch panel circuit board Sensor for CAMS CN15 Switch for Switch for bobinn winder embroidery CN16 Strat/stop Switch etc. USB connector CN17 CPU circuit Foot control board CN18 Power stitch Transformer(Primary) Transformer(Secondary) CN21 LED lamp Main motor Singer Furtura III series...
  • Page 39 CN7 = 23P connect cable.Connected with Switch Board CN21 = Transformer (secondary) CN8 = Drawer for Embroidery CN9 = Motor for material feeding CN10 = Motor for needle position CN11 = Buttonhole Stitch SW CN12 = Thread breakage sensor CN13 = Presser foot Singer Furtura III series...
  • Page 40: Oiling In Shuttle Area And Needle Bar

    1. Remove face cover and then place one or two drops oil at Needle bar clamp (B) & (C). Oiling in Idler pulley 1. Put one drop oil to center shaft of Idler pulley, when removing rear cover. Singer Furtura III series...
  • Page 41: Remove The Hoop Carrier Cover

    When large hoop is attached or no hoop is not attached; Switch is turned off as shown in the left photo. When small hoop is attached; Projection of small hoop pushes the spring to turn on the switch. SW ON Mounting SW OFF plate of small hoop with Mounting plate of projection large hoop without projection Singer Furtura III series...
  • Page 42: Adjustment Origin Position Of Embroidery Foot Along X & Y Axis

    Loosen screw (D) and move sensor plate (E) fi xed on carriage of X axis unit to the right or left for adjustment. If it is shifted to the left, hoop stops early since sensor light is blocked early. If it is shifted to the right, hoop may shift excessively, since sensor light is blocked late, Singer Furtura III series...