Ostat
Code
Name
TEST
1xBC
TEST_CPU_CLOCKS
INIT
1xBC?
INIT_CPU_CLOCKS
INIT
1xCA
RWAY_CPU_ARB
INIT
1xFC
FIND_CPUs
WARN
1xBC
WARN_CPU_CLOCKS
WARN
1xCD
CPU_DECONFIG
WARN
1xCE
CPU_EXTINGUISH
WARN
1xD0
MONARCH_DCNF
WARN
1xEF
ST_WARNING
WARN
1xFy
SLAVE_CPU_FAIL
FLT
1xBA
BOOT_ABDICATION
FLT
1xBB
BAD_CPU_NUMBER
FLT
1xBC
BAD_CLOCKS
FLT
1xBD
BAD_CPU_ORDER
FLT
1xBE
CPU_LOAD_MISSING
FLT
1xBF
BOOT_FAILURE
FLT
1xCB
CPU_REV_BAD
FLT
1xCC
CPU_CACHE_BAD
FLT
1xCE
CPU_EXTINGUISH
FLT
1xCF
SLAVED_FAILED
FLT
1xDF
MONARCH_FAIL_DI
FLT
1xFF
MONARCH_ST_FLT
x = Runway slot number
4–38
Troubleshooting
Table 4–6. Boot Errors
Notes
Test for matching CPU clock speed
Finished test for CPU clock Speed
Initializing Runway CPU arbitration
Synchronizing CPUs
Skipped test for CPU clock speed
CPU was deconfigured
CPU was extinguished due to call to PDC_PROC
Monarch was deconfigured
Selftests returned a warning
M<onarch has stopped a non–responding slave
x = Moxnarch CPU #, y = Slave CPU #
Bad Monarch CPU, x = CPU number
CPU number is greater than 3
Bad CPU clock speed detected
Enforcing CPU ordering
Missing Load Board
Slave CPU halted due to catastrophic boot failure
Mismatched CPU revisions
Mismatched cache sizes
CPU was extinguished via PDC_PROC call
Slave halted itself when selftest status <0
Monarch failed Dual Issue
Selftest returned a failure