Electrical; Wiring Color Code; Electrical Circuit Identification; Field Wiring And Serial Plate Amperage - Hussmann ISLA IM-FR Installation & Operation Manual

Food refrigerated, hot, soup counters
Table of Contents

Advertisement

8
CASE MUST BE GROUNDED
NOTE:
Refer to label illustrated above that is affixed to case
to determine the actual configuration as checked in the
"TYPE iNs Tall ED" boxes.

Electrical Circuit Identification

Standard lighting for all models will be full length fluorescent
lamps located within the case at the top.
The switch controlling the lights, the plug provided for
digital scale, and the thermometer are located at the rear
of the case mullion.
The receptacle that is provided on the exterior back of these
models is intended for computerized scales with a five amp
maximum load, not for large motors or other high wattage
appliances. It should be wired to a dedicated circuit.
PN_3034423_C

Electrical

Electrical s ervice Receptacles
(When a pplicable)
The receptacles located on the exterior of the merchandiser
are intended for scales and lighted displays. They are not
intended nor suitable for large motors or other external
appliances.
This includes (but not limited to) Heaters and Lights.
Field Wiring and Serial Plate
Amperage
Field Wiring must be sized for component amperes printed
on the serial plate. Actual ampere draw may be less than
specified. Field wiring from the refrigeration control panel to
the merchandisers is required for refrigeration thermostats.
Case amperes are listed on the wiring diagram, but always
check the serial plate.
Ballast Location
Ballasts are located within the access panel.
11
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • www.hussmann.com
BEFORE SERVICING
ALWAYS DISCONNECT ELECTRICAL
POWER AT THE MAIN DISCONNECT
WHEN SERVICING OR REPLACING ANY
ELECTRICAL COMPONENT.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Isla im-fhIsla im-fs

Table of Contents