14
3. Apply the sanitizing solution according to the
manufacturer's directions.
4. Rinse thoroughly.
5. Dry completely before resuming operation.
Cleaning Glass and Mirrors
Only use a soft cloth and mild glass cleaner for cleaning
any glass or mirrored components. Be sure to rinse and/
or dry completely.

Access Panels

The electrical J box is located in the center of the case
beneath the plate shelf. The access for condensing units
(in the self contained units) is located on the side of the
stand, at the end. Ends of stand are fitted for removal, if
condensing unit has to be taken out.
BEFORE SERVICING
ALWAYS DISCONNECT ELECTRICAL
POWER AT THE MAIN DISCONNECT
WHEN SERVICING OR REPLACING ANY
ELECTRICAL COMPONENT.
This includes (but not limited to) Fans, Heaters
Thermostats, and Lights.
T-5 Bulbs
T-5 lamps are furnished with a shatterproof protective
coating. The same type of lamp with protective coating
must be used if replaced. All lamps have the label below.
ENCAPSULITE
SHATTERPROOF COATING - SA 10645
U R
Complies with FDA USDA
R
& OSHA Regulations
for replacement call:
1-800-395-9229
Turn switch off then on after replacing bulb
PN_3034423_C
User Information (Contd)

9. Maintenance

NSF
17
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • www.hussmann.com
Never use hot water on cold glass surfaces! it may
shatter and cause serious injury! Allow glass surfaces
to warm first.
Evaporator f ans
The evaporator fans are located at the center front of
these merchandisers directly beneath the display pans.
Should fans or blades need servicing, always replace
fan blades with the raised embossed side of the blade
TOWARD THE MOTOR.
Copper Coils
The copper coils used in Hussmann merchandisers may
be repaired in the field. Materials are available from local
refrigeration wholesalers.
Hussmann recommends using #15 Sil-Fos for repairs.
Tips and Troubleshooting
Before calling for service, check the following:
1. Check electrical power supply to the equipment for
connection.
2. Check fixture loading. Overstocking case will affect
its proper operation.
3. If frost is collecting on fixture and/or product, check
that Humidity Control is working properly, and that
no outside doors or windows are open-allowing
moisture to enter store.
FOR PROMPT SERVICE
When contacting the factory,
be sure to have the Case Model and Serial
Number handy. This information is on a plate
located on the case itself.