Hilti PD 20 Operating Instructions Manual

Hilti PD 20 Operating Instructions Manual

Laser range meter

Advertisement

PD 20
Operating instructions

Advertisement

Table of Contents
loading

Summary of Contents for Hilti PD 20

  • Page 1 PD 20 Operating instructions...
  • Page 2: Table Of Contents

    Make a note of this information in Unit menu / measurement units ..28 the operating instructions and always refer to it 4. Working with the PD 20 ...... 29 when addressing any enquiries to our agents or service department.
  • Page 3: Description Of Functions

    Taking measurements from various Description of functions surfaces ..........34 The Hilti PD 20 is a laser range meter. It makes Using the calculation functions ....35 use of a laser beam to measures distances Adding / subtracting (distances) ..35 within the 0.3 m - 100m range with great...
  • Page 4: Display And Control Panel

    - One-man, hand-held operation for speed of Ambient light too bright - Large display (can be illuminated) Contact a Hilti service department. - Memory function for constants - Built-in calculator functions Operating temperature range of the - Pythagoras button for rapid calculation of...
  • Page 5: Button Functions

    1. Product information 1. Product information Display and control panel, continued Instructions at a glance Button functions Display Select menu Measure LASER Calculate - - - - - Switch on / off Recall last measured values (max. 3) Scroll through active menu Menu select / exit (rEF/CONSt/Light/ dELAY/bEEP/UNIT).
  • Page 6: Technical Data

    *Maximum range depends on reflectance of the target surface and on the brightness of ambient light. If difficulty is experienced (no measure- ment possible), the Hilti PA411 target plate should be used. Measuring time 0.5 to approx. 4 sec. in individual...
  • Page 7: Items Supplied

    One on the side and one underneath (Standard camera tripod thread) Weight 380 g (without batteries) Dimensions 165 x 67 x 47 mm (6.5'’ x 2.6'’ x 1.8'’) Illustration showing dimensions [mm] Qty. Designation PD 20 laser range meter Operating instructions Batteries, type AA Carrying case...
  • Page 8: Safety Information

    Misuse may lead to injury, malfunction This information is intended to enable owners and damage to property. The owner and users of the Hilti PD 20 to identify any must inform the user of the operating operating risks in good time, i.e. to eliminate any risks associated with the equipment such risks in advance where possible.
  • Page 9: Operating Risks

    Failure to adequately cordon off the industrial accident prevention regulations. area in which you are measuring may • To notify Hilti immediately of any safety- lead to dangerous situations in road related defects or deficiencies in the traffic, on building sites or in industrial equipment.
  • Page 10 2. Safety information 2. Safety information Operating risks, continued Operating risks, continued Preventative measures CAUTION – Take individual measurements If the equipment is not used for – Set up the tool in a fixed position (tripod) lengthy periods, there is a risk of it being damaged by leaking batteries.
  • Page 11: Disposal

    2. Safety information Disposal Laser classification WARNING The Hilti PD 20 generates a visible laser beam Improper disposal of the equipment which is emitted from the front side of the tool. may lead to the following: The product conforms to laser class 2 as per: •...
  • Page 12: Information Plate

    Max. power output: Caution The product should be repaired at a Hilti-approved service centre only. Information plate All product identification data and warnings concerning the use of the product can be found on the rear of the Hilti PD 20. continued...
  • Page 13: Electromagnetic Compatibility (Emc)

    Electromagnetic compatibility (EMC) 3. Operation Inserting the batteries Electromagnetic compatibility refers to the ability Symbol displayed of the Hilti PD 20 to function correctly in an environment where it is exposed to Low battery voltage electromagnetic radiation and electrostatic Insert new batteries...
  • Page 14: Menu Selection And Setting

    3. Operation 3. Operation Menu selection and setting Selecting and setting the menu, continued CONST menu / constants Menu overview Press the button CONSt Light MENU to select menu mode. dELAY bEEP UNIT Use the CONST buttons to select the Select / exit menu mode 0.234 CONST menu.
  • Page 15: Beep Menu / Beep Sound

    3. Operation 4. Working with the PD 20 Selecting and setting the menu, continued 4. Working with the PD 20 bEEP menu / beep sound Measuring distances Press the button Switch on the tool. MENU to select menu mode. The following is displayed:...
  • Page 16: Measuring Using The Spike

    4. Working with the PD 20 4. Working with the PD 20 Measuring distances, continued Measuring distances, continued Measuring using the spike Continuous measurement (tracking) The spike should be folded out when measuring Switch on the tool. the diagonals of a room or when taking measurements from corners where access is difficult.
  • Page 17: Measuring Using The Self-Timer

    One of the two threaded bushings (1/4" tripod thread) on the PD 20 can be used for attaching an extension rod. When an extension rod is used, the delay between pressing the “measure”...
  • Page 18: Taking Measurements From Various Surfaces

    Matt green surfaces measured from the same line on a wall. decrease the range of the PD 20. Press the “measure” button. The laser beam is switched on. For the first part...
  • Page 19: Multiplication (Areas / Volumes)

    4. Working with the PD 20 4. Working with the PD 20 Using the calculation functions, continued Using the calculation functions, continued Example Multiplication (areas / volumes) Calculating the volume of a room Example After calculating the floor area of the room,...
  • Page 20: Calculating With Pythagoras

    4. Working with the PD 20 4. Working with the PD 20 Using the calculation functions, continued Measuring distances, continued Calculating with Pythagoras, continued Calculating with Pythagoras 2. Measure the adjacent side The Pythagoras function button can be used, for example, for quickly measuring remote heights etc.
  • Page 21: Calculating Using A Constant Value

    Check the accuracy of the equipment before it is used after a long period of storage or transportation. Transportation Your equipment should be shipped in the Hilti shipping carton or packaging of similar quality. Always remove the batteries before shipping.
  • Page 22: Symbols Displayed

    General hardware fault equal to 5mm. Solution A PD 20 which has been tested / inspected over Contact a service centre. the test distance will operate with the accuracy specified in the operating instructions over the entire specified length and temperature range.
  • Page 23: Accessories

    8. Accessories 9. FCC statement (applicable in US) 8. Accessories 9. FCC statement (applicable in US) WARNING Batteries This equipment has been tested and 2 type AA 1.5V alkaline batteries found to comply with the limits for a Replacement batteries can be purchased class B digital device, pursuant to part locally.
  • Page 24: Ec Declaration Of Conformity

    10. EC declaration of conformity 11. Warranty 10. EC declaration of conformity 11. Warranty Hilti warrants the supplied device to be free from Designation: PD 20 defective materials and workmanship. This Serial number: 00000001-50000000 warranty is only valid on condition that the...
  • Page 25 Hilti = Registered trademark of Hilti Corp., Schaan Right of technical and programme changes reserved W2363 1199 10 englisch 9 Printed in Liechtenstein ©1999 S.E.&O.

Table of Contents