Hilti Entwicklungsgesellschaft mbH | Tool Certification | Hiltistraße 6 | 86916 Kaufering, DE 1.6 Product information Hilti products are designed for professional use and may be operated, serviced and maintained only by trained, authorized personnel. This personnel must be informed of any particular hazards that may be encountered.
Page 8
CAUTION Possible hazards as result of short circuiting, overload and fire. Possible hazards due to heat radiation, ejection of molten material or chemical reactions caused by short circuiting, overloading or through resulting fire. ▶ Do not expose the product to high temperatures or fire. The battery contained in the tool could explode or release toxic substances.
Accuracy must be checked by taking measurements by other means when working under such conditions or if you are unsure. Likewise, Hilti cannot rule out the possibility of interference with other devices (e.g. aircraft navigation equipment). The laser range meter complies with the requirements of class A: The possibility of interference occurring in a domestic environment cannot be excluded.
▶ Store laser tools, when not in use, in places to which unauthorized persons have no access. 2.5 General safety rules ▶ Check the product for damage before use. Have the damage repaired by Hilti Service. ▶ Before using the product, just to be sure, check the product’s preset settings and any settings you have made yourself.
The charging operation may even be automatically interrupted in order to maintain a safe battery temperature. The charging operation may take longer if the USB cable supplied by Hilti is connected to a PC for charging. We do not recommend using micro-USB cables from other manufacturers. If this cannot be avoided, you should first ensure that the cable in question is suitable for use with 5.0 V/2.1 A power sources.
3.5 Technical data 3.5.1 Distance measurement Note Distance and inclination measurement accuracy: Influences such as high temperature fluctuations, dampness, shock, dropping, etc. can affect the accuracy of the tool. Unless stated otherwise, the tool was adjusted or calibrated under standard ambient conditions (MIL-STD-810G). As a basic principle, when taking distance measurements an additional distance-dependent error of 0.02 mm per meter is to be taken into account.
3.7 Navigating on the display 3.7.1 Preparations at the workplace CAUTION Risk of injury! Inadvertent starting of the product. ▶ Remove the battery before making any adjustments to the power tool or before changing accessories. Observe the safety instructions and warnings in this documentation and on the product. 3.7.2 Start page The tool’s start page contains links to the following pages:...
3.7.4 Toolbar The toolbar is displayed during the measurement. It allows you to activate assistants, switch between the permanent laser and the standard laser, switch on the aiming camera and change the reference position. 3.7.5 Navigation bar The navigation bar is always found at the lower edge of the display, and includes the following elements: •...
▶ If the folding spike has been flattened by use, or if you have lost the folding spike, please contact Hilti Service. 3.10.3 Fitting a measuring extension to the base of the tool Note A measuring extension will be detected automatically (and taken into account accordingly) only when...
3.12.2 The influence of surfaces on the measurement The Hilti laser module, developed on the basis of PulsePower (millions of pulses per second), offers the best conditions for reception of an ample number of distinct samples of reflected laser light, which are used to calculate precise measurements.
angles, as far as possible, as otherwise the light will be reflected in a different direction and too little light will return to the tool to calculate a measurement. Curved surfaces can also make it more difficult to reflect enough light in the direction of the tool for a measurement to be taken.
Possible combinations of assistants and functions Assistant Function Trigger Timer Aiming camera ‘Direct’ ✓ ✓ ✓ ‘Measure from picture’ ✓ ✓ ✓ ‘Draw in Picture’ ✓ ✓ ✓ ‘Area and Volume’ ✓ ✓ ✓ ‘Indirect’ ✓ ✓ ✓ ‘Not reflecting’ Yes, for the first mea- Yes, for the first mea- ✓...
Zoom Tapping on the lower edge of the screen activates the zoom setting. A bar on the upper edge of the screen shows the current magnification as a percentage. Swiping left or right on the lower edge of the screen allows you to adjust the magnification.
◁ Continuous measurement ends and the shortest distance determined during continuous measurement is displayed. 4.2.4 Trigger ‘Maximal’ The tool records the greatest distance registered during continuous measurement. Note This measuring program is particularly helpful if a measurement has to be taken in a hard-to-reach area, such at the corner of a ceiling.
4.3 Measurements, managing project folders and exporting data 4.3.1 Measurements The tool saves measurements, photos of the measured targets and any calculations that have been carried out. Each result can be supplemented with annotations or a photo. With average camera settings and ordinary use, approxi- mately 3000 results can be saved.
Third-party applications may be used at the discretion of the user and at his or her own responsibility. The terms of business or login configurations may change through use of third-party applications. Hilti accepts no responsibility and provides no support for third-party applications.
subfolders for all of the exports, chronologically ordered by the date and time of the export as well as by the name of the project or result. ▶ Copy the folder or specific files in the pdc_export directory to your PC. 4.4 Point measurements and range (multiple) measurements Distance measurements can be carried out as point or range (multiple) measurements.
If the battery is fully charged and Bluetooth is deactivated, the tool can remain in standby mode for between one week and one month before it has to be recharged. This means that standby mode is ideal for normal daily use. 5.2.3 Activating standby mode ▶...
3. Select "More...". ◁ The tool searches for suitable Bluetooth devices. 4. In the settings on the device to which you want to connect the tool, ensure that the device is visible to other devices and that it is able to connect to new devices. Further information may be included in the documentation for the respective devices.
Setting Description ‘PD-C project export’ The Hilti logo that appears at top left of PDF reports can be set to “on” or “off”. Standard setting: On ‘Please choose valid image type The user’s business card can be shown or hidden (on the PDF re- (jpg/png)’...
6.2.1 ‘Measure from picture’ This function provides approximate values for distances you plot with lines along certain elements in the picture. These lines must be drawn on a level surface (2D), such as on a wall, facade or ceiling. Examples of applications for the ‘Measure from picture’ function: •...
Note You can repeat the following steps at any time if you reopen the picture in the project folder. 4. Tap the pencil icon. ◁ The line icon and the icon for annotations appear and then fade out after a few seconds. Note If the icons have faded out, tap the picture to display the icons again.
◁ The volume is displayed. 6.4 Indirect measurements 6.4.1 Using indirect measurements Note The accuracy of measurements taken using the ‘Indirect’ and ‘Pythagoras’ functions is primarily dependent on whether the reference position is kept constant. This is not easy to achieve if the tool is simply held by hand, without any form of support.
◁ The result is displayed. Note Adjust the inclination sensor at regular intervals ( → page 24). This helps ensure high measuring accuracy . 6.4.4 Measuring vertical distances indirectly 1. Select the option ‘Indirect’ and ‘Vertical’ from the ‘Functions’ menu. 2.
Note Take care to ensure that the reference position remains unchanged during the entire measuring operation. Use of the short measuring extension is helpful. This indirect function makes use of the angle sensor, which works only with a vertical pivot. In other words, the display can face upwards or downwards, but should not be tilted to the left or right.
Note When taking the measurement at right angles it is important to adhere exactly to the 90° angle. Take care to ensure that the reference position remains unchanged during the entire measuring operation. Use of the short measuring extension is helpful. As the Pythagoras functions do not make use of the inclination sensor, the tool can be pivoted in any direction.
▶ Wipe the touchscreen with a clean, non-abrasive cloth so that it is shiny and responsive to the touch. ▶ Stop using the tool if the touchscreen is broken and contact Hilti Service. 7.3 Adjusting the inclination sensor ▶...
Page 36
Most of the materials from which Hilti tools and appliances are manufactured can be recycled. The materials must be correctly separated before they can be recycled. In many countries, your old tools, machines or appliances can be returned to Hilti for recycling. Ask Hilti Service or your Hilti representative for further information.
Page 37
Consult the dealer or an experienced TV/radio technician for assistance. Note Changes or modifications not expressly approved by Hilti may restrict the user’s authorization to operate the equipment. This device is in compliance with paragraph 15 of the FCC Regulations RSS-210 of the ISED Regulations.
Page 38
Adjusting the inclination sensor ........Aiming camera .