Removing a management-module interposer

To remove a management-module interposer or tray filler, complete the following
steps.
1. Read the safety information that begins on page vii and "Installation guidelines"
2. Remove the bezel, if installed, to access the management-module interposer to
3. If a management module or filler is installed in the management-module bay,
4. Pull the management-module interposer release handle to the open position.
5. Pull the interposer out of the bay. Within 1 minute, install either another module
6. If you are instructed to return the interposer, follow all packaging instructions
on page 31.
be removed (see "Removing a bezel collar" on page 41).
remove it (see "Removing a management module" on page 75).
The interposer moves out of the bay approximately 0.6 cm (0.25 inch).
or a filler into the module bay.
and use any packaging materials for shipping that are supplied to you.