Command
Function (Ambit)
&G2
Enable 1800 Hz guard tone
&J0
Set S-Register response only for compatibility
&J1
Set S-Register response only for compatibility
&K0
Disable DTE/DCE flow control
&K3
Enable RTS/CTS DTE/DCE flow control
&K4
Enable XON/XOFF DTE/DCE flow control
&K5
Enable transparent XON/ XOFF low control
&K6
Enable both RTS/CTS and XON/XOFF flow control
&L0
Select dial up line operation
&M0
Select direct asynchronous mode
&M1
Select sync connect with async off-line command mode
&M2
Select sync connect with async off-line command mode and enable DTR dialing of directory zero
&M3
Select sync connect with async off-line command mode and enable DTR to act as Talk/Data switch
&P0
Set 10 pps pulse dial with 39%/61% make/break
&P1
Set 10 pps pulse dial with 33%/67% make/break
&P2
Set 20 pps pulse dial with 39%/61% make/break
&P3
Set 20 pps pulse dial with 33%/67% make/break
&Q0
Select direct asynchronous mode
&Q1
Select sync connect with async off-line command mode
&Q2
Select sync connect with async off-line command mode and enable DTR dialing of directory zero
&Q3
Select sync connect with async off-line command mode and enable DTR to act as Talk/Data switch
&Q4
Select Hayes AutoSync mode
&Q5
Modem negotiates an error corrected link
&Q6
Select asynchronous operation in normal mode
&R0
CTS tracks RTS (sync) or CTS is normally ON and will turn OFF only if required by flow control (async)
&R1
CTS is always active (sync) or CTS is normally ON and will turn OFF only if required by flow control (async)
&S0
DSR is always active
&S1
DSR will become active after answer tone has been detected and inactive after the carrier has been lost
&T0
Terminate any test in progress
&T1
Initiate local analog loopback
&T2
Returns ERROR result code
&T3
Initiate local digital loopback
&T4
Allow remote digital loopback (RDL)
&T5
Disallow remote digital loopback request
&T6
Request an RDL without self-test
&T7
Request an RDL with self-test
&T6
Request an RDL without self-test
&T7
Request an RDL with self-test
&T8
Initiate local analog loop with self-test
&V
Display current configuration and stored profiles
&V1
Display last connection statistics
&W0
Store the current configuration as profile 0
&W1
Store the current configuration as profile 1
&X0
Select internal timing for the transmit clock
&X1
Select external timing for the transmit clock
&X2
Select slave receive timing for the transmit clock
&Y0
Recall stored profile 0 upon power up
&Y1
Recall stored profile 1 upon power up
&Zn=x
Store dial string x (up to 34 digits) to location n (0 to 3)