REDUCED GAS FLOW RATE SETTING FOR HOB TAPS
1. Ignite the burner that is to be adjustment and turn the knob
to the reduced position.
2. Remove the knob from the gas tap.
3. Use an appropriately sized screwdriver to adjust the flow
rate adjustment screw. For LPG (butane-pro pane) turn the screw
clockwise. For the naturel gas, you should turn the screw counter-
clockwise once.
"The normal length of a straight flame in the reduced position
should be 6-7 mm."
4. If the flame is higher than the desired position, turn the screw
clockwise. If it is smaller turn anticolockwise.
5. For the last control, bring the burner both to hight-flame and
reduced positions and check whether the flame is on or off.
Depending on the type of gas tap used in your appliance the
adjustment screw position may vary.
To adjust your oven acc. to the gas type, make the adjustment
for reduced flame carefully by turning with a small screwdriver
as shown below on the screw in the middle of the gas cocks as
well as nozzle changes (figure 6).
WARNING: Do not completely remove the flow rate adjustment
screw from the valve stem. The flow rate adjustment screw is an
integral part of gas valve assembly. Removing the flow rate
adjustment screw will cause gas to leak. After adjusting the flow
rate adjustment screw, inspect the assembly for gas leaks.