Samsung NY90T5010SS User & Installation Manual page 23

Free standing oven
Table of Contents

Advertisement

NOZZLE CHANGE OPERATION
1. Please use driver with special head for removed and install
nozzle as. (figure 3)
2. Please remove nozzle (figure 4) from burner with special
nozzle driver and install new nozzle. (figure 5)
Figure 3
VENTILATION OF ROOM
The air needed for burning is received from room air and the
gases emitted are given directly in room. For safe operation
of your product, good room ventilation is a precondition. If no
window or room to be utilized for room ventilation is available,
additional ventilation should be installed. However, room has a
door opening outside, it is no needed to vent holes.
Room size
Smaller than 5 m³
Between 5 m³ - 10 m³
Bigger than 10 m³
In basement or cellar
Figure 4
Ventilating opening
23
Figure 5
min. 100 cm²
min. 50 cm²
no need
min. 65 cm²