Blower And Motor - Vulcan-Hart VC5E Service Manual

Full size electric
Table of Contents

Advertisement

VC5ED FULL SIZE ELECTRIC CONVECTION OVEN - REMOVAL AND REPLACEMENT OF PARTS
6.
Pull elements forward, then away from right wall.
Fig. 12
7.
Reverse the procedure to install the replacement
heating element.

BLOWER AND MOTOR

electrical power to the machine and
follow lockout / tagout procedures.
1.
Take out the racks and rack supports.
2.
Lift off FAN COVER.
3.
If replacing:
A.
Blower Only - Loosen bolts on blower hub
and using a bearing puller, remove blower
from motor shaft.
1)
Reverse procedure to install and
perform BLOWER ADJUSTMENT.
B.
Motor - perform step 3A and continue
procedure.
4.
Remove bolts that secure the motor mounting
plate to the rear wall.
Disconnect the
Page 9 of 31
Fig. 13
5.
Place a piece of cardboard on the bottom of the
oven cavity to protect its surface from any
damage during motor assembly removal.
6.
Pull the motor assembly into the oven cavity and
place it on the cardboard.
7.
Remove the junction box cover from the motor,
disconnect lead wires and remove the conduit.
8.
Remove motor mounting bolts and flat washers
then lift the motor from the mounting plate.
9.
Position the replacement motor on the motor
mounting plate and install mounting bolts and
washers. Hand tighten mounting bolts only.
Fig. 14
10. Reconnect lead wires at the motor, replace
conduit and junction box cover.
F45652 (0217)