Blower Adjustment; Door Strike Adjustment (Independent Doors) - Vulcan-Hart VC5E Service Manual

Full size electric
Table of Contents

Advertisement

VC5ED FULL SIZE ELECTRIC CONVECTION OVEN - SERVICE PROCEDURES AND ADJUSTMENTS
HEATING ELEMENT VALUES
KW PER
VOLT.
ELEMENT
1 PH
208
4
240
4
16.5
480
4
1.
Values in the table are nominal.
Tolerance is +5/-10%.
NOTES:
2.
Voltage values are @ 60HZ.
3.
Resistance values (ohms) are @
room temperature.

BLOWER ADJUSTMENT

electrical power to the machine and
follow lockout / tagout procedures.
1.
Loosen the motor mounting bolts.
2.
Adjust the motor position until the blower is
parallel to and 1/4 inch away from the motor
mounting plate. Check for squareness of the
blower to the motor mounting plate at the top,
bottom, left and right of the blower.
A.
If the blower is square then tighten motor
mounting bolts and proceed to STEP 4.
B.
If the blower is not square continue
adjusting until proper spacing is achieved
then tighten motor mounting bolts.
NOTE: If necessary, place shims between motor and
frame.
Fig. 24
AMPS PER
OHMS PER
ELEMENT
ELEMENT
3 PH
19
19
10
16.5
14.5
8
8
57
Disconnect the
3.
Reverse the procedure to install.
DOOR STRIKE ADJUSTMENT
(INDEPENDENT DOORS)
1.
Open the doors and inspect door strike for proper
shape.
A.
Bend strike plate.
2.
Open and close the doors several times while
observing the roller latch and strike plate
operation.
A.
Replace ROLLER LATCH ASSEMBLY
(INDEPENDENT DOORS) if
malfunctioning.
3.
Each oven door should open with a force of 8 to
25 pounds when pulled at the handle. The
adjustments must allow the doors to remain
closed during normal operation and allow
opening without exertion by the user.
Page 17 of 31
Fig. 25
Fig. 26
F45652 (0217)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vc5ed

Table of Contents