Onto control box
4
Fix the wall plate of the user interface
to the front panel of the control box
using the M4 bolts and nuts from the
accessory bag.
Be careful NOT to distort the shape
of the backside of the user interface
by overtightening the mounting
screws.
2
1
4
5
Connect as shown in 4A.
6
Reconnect the faceplate to the wall plate.
Be careful NOT to pinch the wiring when connecting the
front panel to the control box.
4A From the rear
PCB
a
b
4C From the top
a
b
PCB
b
a
Notch this part for the wiring to pass through with nippers
etc.
b
Secure the wiring to the front part of the casing using the
wiring retainer and clamp.
7.8.7

To connect the shut-off valve

1 Connect the valve control cable to the appropriate terminals as
shown in the illustration below.
NOTICE
Only connect NO (normal open) valves.
Installer reference guide
44
In the room
Fix the wall plate of
the user interface to
the wall.
When NOT
connecting a user
interface to the
control box, do NOT
remove the plugs
from the holes in the
3
front plate.
Connect as shown
in 4A, 4B, 4C or 4D.
4B From the left
PCB
a
b
4D From the top centre
a
b
PCB
b
NO
X5M
X3M
INFORMATION
By default, the shut‑off valve is to be connected to the
outdoor unit. However, if control box EKCB07CAV3 is
present in the system, you can also connect it to the
control box. To do this, connect outdoor unit terminals
X3M/1+2 to control box terminals X8M/6+7, and then
connect the shut‑off valve to control box terminals
X8M/6+7.
X2M
6 7
X8M
M2S
7.8.8

To connect the domestic hot water pump

1 Connect outdoor unit terminals X3M/3+4 to the bottom side of
terminals X8M/8+9 of control box EKCB07CAV3.
2 Connect the cable of the domestic hot water pump to the
bottom side of control box terminals X8M/8+9.
X2M
8 9
X8M
M
M2P
1~

EBLQ+EDLQ011~016CAV3+W1 + EK(2)CB07CAV3 +

Daikin Altherma low temperature monobloc
X4M
M2S
X3M
X5M
X3M
X5M
EKMBUHCA3V3+9W1