Overview Of Electrical Connections For External And Internal Actuators - Daikin Altherma EDLQ011-016CW1 Installer's Reference Manual

Low temperature monobloc
Hide thumbs Also See for Altherma EDLQ011-016CW1:
Table of Contents

Advertisement

6 Preparation
Normal power
Preferential kWh rate power supply
supply
Power supply is
NOT interrupted
a
b
0
0
58 0
1 5 0
5
5
1
4
3
2
f
e
f
e
d
c
3
During preferential
kWh rate power
supply activation,
power supply is NOT
interrupted. The
outdoor unit is turned
off by the control.
Remark: The
electricity company
must always allow the
power consumption
of the hydro part of
the outdoor unit (and
of the control box, if
part of the system).
a
Normal power supply
b
Preferential kWh rate power supply
c
Hydro part of the outdoor unit
d
Refrigerant part of the outdoor unit
e
Control box
f
Backup heater kit
1
Power supply for outdoor unit
2
Interconnection cable to control box
3
Interconnection cable to backup heater kit
4
Power supply for control box
5
Power supply for backup heater kit
6
Preferential kWh rate power supply (voltage free contact)
7
Normal kWh rate power supply (to power the hydro part of
the outdoor unit in the event of a power supply interruption
of the preferential kWh rate power supply)
6.4.4
Overview of electrical connections for
external and internal actuators
The following illustration shows the required field wiring.
INFORMATION
The following illustration is an example and might NOT
match your system layout.
Installer reference guide
30
Power supply is
interrupted
a
b
0
0
0
0
58 0
58 0
0
0
58 0
1 5 0
1 5 0
1 5 0
5
4
7
1
4
6
3
6
2
f
e
c
2
d
c
During preferential
kWh rate power
supply activation,
power supply is
interrupted
immediately or after
some time by the
electricity company.
In this case, the
hydro part of the
outdoor unit (and the
control box, if part of
the system) must be
powered by a
separate normal
power supply.
1
2
13
5
21
M
11
15
14
1
18
22
a
23
d
e
17
19
16
M
6
a
Backup heater kit
b
Outdoor unit
c
Control box
d
Option box
e
Domestic hot water tank
Outdoor unit
Item
Description
Power supply
1
Power supply for
outdoor unit
2
Normal kWh rate power
supply
User interface
3
User interface
Optional equipment
4
Remote outdoor sensor 2
Field-supplied components
5
Space heating/cooling
operation control (or
shut‑off valve)
(a)
Refer to name plate on outdoor unit.
(b)
Cable section 0.75 mm² till 1.25 mm²; maximum length:
500 m. Applicable for both single user interface and dual
user interface connection.
(c)
Minimum cable section 0.75 mm².
Control box
Item
Description
Power supply
6
Power supply for
control box
Interconnection cable
7
Interconnection cable
between outdoor unit
and control box
8
Interconnection cable
for the user interface
(between outdoor unit
and control box)
EBLQ+EDLQ011~016CAV3+W1 + EK(2)CB07CAV3 +
b
4
3
9
10 7 8
12
c
20
d
25
24
Wires
(a)
2+GND or
3+GND
2
6.3 A
(b)
2
(c)
(c)
2
Wires
(a)
2+GND
(b)
2
(c)
2
EKMBUHCA3V3+9W1
Daikin Altherma low temperature monobloc
4P522034-1 – 2018.01
28
30
29
27
26
Maximum
running
current
Maximum
running
current

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents