Daikin Altherma EDLQ011-016CW1 Installer's Reference Manual page 103

Low temperature monobloc
Hide thumbs Also See for Altherma EDLQ011-016CW1:
Table of Contents

Advertisement

Field settings table
Breadcrumb
Field code
Setting name
└─ Boiler efficiency
A.6.A
[7-05]
└─ Emergency
A.6.C
└─ Overview settings
A.8
[0-00]
Leaving water value for high ambient temp. for LWT add zone heating WD curve.
A.8
[0-01]
Leaving water value for low ambient temp. for LWT add zone heating WD curve.
A.8
[0-02]
High ambient temp. for LWT add zone heating WD curve.
A.8
[0-03]
Low ambient temp. for LWT add zone heating WD curve.
A.8
[0-04]
Leaving water value for high ambient temp. for LWT add zone cooling WD curve.
A.8
[0-05]
Leaving water value for low ambient temp. for LWT add zone cooling WD curve.
A.8
[0-06]
High ambient temp. for LWT add zone cooling WD curve.
A.8
[0-07]
Low ambient temp. for LWT add zone cooling WD curve.
A.8
[0-0B]
Leaving water value for high ambient temp. for DHW WD curve.
A.8
[0-0C]
Leaving water value for low ambient temp. for DHW WD curve.
A.8
[0-0D]
High ambient temp. for DHW WD curve.
A.8
[0-0E]
Low ambient temp. for DHW WD curve.
A.8
[1-00]
Low ambient temp. for LWT main zone heating WD curve.
A.8
[1-01]
High ambient temp. for LWT main zone heating WD curve.
A.8
[1-02]
Leaving water value for low ambient temp. for LWT main zone heating WD curve.
A.8
[1-03]
Leaving water value for high ambient temp. for LWT main zone heating WD curve.
A.8
[1-04]
Weather dependent cooling of the main leaving water temperature zone.
A.8
[1-05]
Weather dependent cooling of the additional leaving water temperature zone.
A.8
[1-06]
Low ambient temp. for LWT main zone cooling WD curve.
A.8
[1-07]
High ambient temp. for LWT main zone cooling WD curve.
A.8
[1-08]
Leaving water value for low ambient temp. for LWT main zone cooling WD curve.
A.8
[1-09]
Leaving water value for high ambient temp. for LWT main zone cooling WD curve.
A.8
[1-0A]
What is the averaging time for the outdoor temp?
A.8
[2-00]
When should the disinfection function be executed?
A.8
[2-01]
Should the disinfection function be executed?
A.8
[2-02]
When should the disinfection function start?
A.8
[2-03]
What is the disinfection target temperature?
A.8
[2-04]
How long must the tank temperature be maintained?
A.8
[2-05]
Room antifrost temperature
A.8
[2-06]
Room frost protection
A.8
[2-09]
Adjust the offset on the measured room temperature
A.8
[2-0A]
Adjust the offset on the measured room temperature
A.8
[2-0B]
What is the required offset on the measured outdoor temp.?
A.8
[3-00]
Is auto restart of the unit allowed?
A.8
[3-01]
--
A.8
[3-02]
--
A.8
[3-03]
--
A.8
[3-04]
--
A.8
[3-05]
--
A.8
[3-06]
What is the maximum desired room temperature in heating?
A.8
[3-07]
What is the mimimum desired room temperature in heating?
A.8
[3-08]
What is the maximum desired room temperature in cooling?
A.8
[3-09]
What is the minimum desired room temperature in cooling?
(*1) *B*_(*2) *D*
Range, step
Default value
R/W
0: Very high
1: High
2: Medium
3: Low
4: Very low
R/W
0: Manual
1: Automatic
R/W
[9-05]~min(45, [9-06])°C, step: 1°C
35⁰C
R/W
[9-05]~[9-06]°C, step: 1°C
45⁰C
R/W
10~25°C, step: 1°C
15⁰C
R/W
-40~5°C, step: 1°C
-10⁰C
R/W
[9-07]~[9-08]°C, step: 1°C
8⁰C
R/W
[9-07]~[9-08]°C, step: 1°C
12⁰C
R/W
25~43°C, step: 1°C
35⁰C
R/W
10~25°C, step: 1°C
20⁰C
R/W
35~[6-0E]°C, step: 1°C
55⁰C
R/W
45~[6-0E]°C, step: 1°C
60⁰C
R/W
10~25°C, step: 1°C
15⁰C
R/W
-40~5°C, step: 1°C
-10⁰C
R/W
-40~5°C, step: 1°C
-10°C
R/W
10~25°C, step: 1°C
15°C
R/W
[9-01]~[9-00], step: 1°C
45°C
R/W
[9-01]~min(45, [9-00])°C , step: 1°C
35°C
R/W
0: Disabled
1: Enabled
R/W
0: Disabled
1: Enabled
R/W
10~25°C, step: 1°C
20°C
R/W
25~43°C, step: 1°C
35°C
R/W
[9-03]~[9-02]°C, step: 1°C
22°C
R/W
[9-03]~[9-02]°C, step: 1°C
18°C
R/W
0: No averaging
1: 12 hours
2: 24 hours
3: 48 hours
4: 72 hours
R/W
0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunday
R/W
0: No
1: Yes
R/W
0~23 hour, step: 1 hour
23
R/W
55~75°C, step: 5°C
70°C
R/W
5~60 min, step: 5 min
10 min
R/W
4~16°C, step: 1°C
16°C
R/W
0: Disabled
1: Enabled
R/W
-5~5°C, step: 0,5°C
0°C
R/W
-5~5°C, step: 0,5°C
0°C
R/W
-5~5°C, step: 0,5°C
0°C
R/W
0: No
1: Yes
0
1
4
2
1
R/W
18~30°C, step: A.3.2.4
30°C
R/W
12~18°C, step: A.3.2.4
16°C
R/W
25~35°C, step: A.3.2.4
35°C
R/W
15~25°C, step: A.3.2.4
15°C
5/9
Installer setting at variance with
default value
Date
Value
4P522033-1 - 2018.01